BTL PF _ 400- _ _ _ _ -C15A _ _ _ _ - _ _ _ _ _ _
Magnetostrictive Linear Position Sensor – Profile Style
9

Technical data

The specifications are typical values for
BTL PF _ 400- _ _ _ _ -C15A _ _ _ _ - _ _ _ _ _ _ with 24 V DC
and at room temperature and with a measuring length of
500 mm in conjunction with the magnet BTL5-P-3800-2,
BTL5-P-4500-1, BTL5-P-5500-2, BTL6-A-3800-2,
BTL6-A-3801-2, BTL5-F-28141-S or BTL5-T-28141-S.
The product is immediately ready for operation, full
accuracy is achieved after the warm-up phase.
Further data can be found at www.balluff.com
on the product page.
9.1

Ambient conditions

Ambient temperature
Storage temperature
Relative humidity
Typ. temperature coefficient
1)
Shock rating as per
EN 60068-2-27
2), 3)
Continuous shock per
EN 60068-2-27
2), 3)
Vibration per EN 60068-2-6
2), 3)
Protection per IEC 60529 (when
threaded together)
9.2

Detection range/Measuring range

Measuring length
Analog resolution
...-C15AA/-C15A1...
...-C15AE/C/-C15A5/3...
Repeat accuracy
Measuring length ≤ 500 mm
Measuring length > 500 mm
Length-dependent measuring
frequency
...-C15A_ _ _0-...
Measuring length ≤ 1270 mm
Measuring length > 1270 to
≤ 2650 mm
Measuring length > 2650 mm
...-C15A_ _CA-... (High update rate)
Measuring length ≤ 240 mm
Measuring length > 240 to
≤ 590 mm
Linearity deviation
4)
with measuring length ≤ 500 mm
with measuring length > 500 to
≤ 4000 mm
Detectable speed
www.balluff.com
9.3
Operating voltage U
Current draw (at 24 V DC)
Power consumption
−25...+85 °C
−40...+100 °C
Overvoltage protection
≤ 90%, non-
condensing
Voltage-proof up to (GND – Housing)
≤ 30 ppm/K
...-C15AA/C15A1...
100 g/6 ms
...-C15AE/C/C15A5/3...
50 g/2 ms
12 g, 10
9.4
...2000 Hz
Short circuit protection
IP67
Protected against polarity reversal
25...4000 mm
Measuring length 500 mm, magnet in the middle of the measuring range
1)
2)
Individual specifications as per Balluff standard
Resonant frequencies excluded
3)
183 μV / ≥ 4 μm
Configuration for one magnet
4)
351 nA / ≥ 4 μm
A prerequisite is that no current can flow between GND and 0 V in the
5)
event of polarity reversal.
≤ ± 10 µm
≤ ± 0.002% FS
1000 Hz
500 Hz
250 Hz
4000 Hz
2000 Hz
≤ ± 60 µm
≤ ± 0.012% FS
≤ 10 m/s

Electrical data

b
...-C15AA_ _0-.../...-C15A1_ _0-... ≤ 80 mA
...-C15AE/C_ _0-.../
...-C15A5/3_ _0-...
...-C15AA_ _A-.../...-C15A1_ _A-... ≤ 90 mA
...-C15AE_ _A-.../...-C15A5_ _A-... ≤ 120 mA
...-C15AA_ _0-.../...-C15A1_ _0-... ≤ 2.0 W
...-C15AE/E_ _0-.../
...-C15A5/3_ _0-...
...-C15AA_ _A-.../...-C15A1_ _A-... ≤ 2.2 W
...-C15AE_ _A-.../...-C15A5_ _A-... ≤ 2.9 W
Output current
Load resistance R
Lc

Electrical connection

10...30 V DC
≤ 110 mA
≤ 2.7 W
U
up to 36 V DC
b
500 V DC
≤ 5 mA
≤ 500 ohm
Signal output to
GND and
30 V DC
U
up to 30 V DC
5)
b
english