10. The work area must exceed 30 m³ and sufficient
ventilation must be ensured during spraying and
drying.
11. Do not spray against the wind. Always adhere to
the regulations of the local police authority when
spraying combustible or hazardous materials.
12. Do not process media such as white spirit, butyl
alcohol and methylene chloride with the PVC
pressure hose.
13. These media will destroy the pressure hose.
14. The work area must be separated from the
compressor so that it cannot come into direct
contact with the working medium.
Operation of pressure vessels
• Anyone who operates a pressure vessel must keep
this in good working order, operate and monitor
it correctly, perform the necessary maintenance
and servicing works immediately and implement
safety measures as required according to the
circumstances.
• The regulatory authority can instruct necessary
monitoring measures in individual cases.
• A pressure vessel must not be operated if it exhibits
a defect that poses a danger to personnel or third
parties.
• Check the pressure vessel for rust and damage
each time before use. The compressor shall not
be operated if the pressure vessel is damaged or
rusty. If you discover damage, please contact the
customer service workshop.
Warning! This power tool generates an electromagnetic
field during operation. This field can impair active or
passive medical implants under certain conditions. In
order to prevent the risk of serious or deadly injuries,
we recommend that persons with medical implants
consult with their physician and the manufacturer of
the medical implant prior to operating the power tool.
Keep these safety instructions in a safe place.
6. Residual risks
The machine has been built according to the state-
of-the-art
and
the
recognised
requirements. However, individual residual risks can
arise during operation.
• Health hazard due to electrical power, with the use
of improper electrical connection cables.
24 | GB
• Furthermore, despite all precautions having been
• Residual risks can be minimised if the "Safety
• Avoid accidental starting of the machine: the
• Keep your hands away from the work area, when the
7.
Mains connection
Motor power
Operating mode
Compressor speed
Pressure vessel capacity
Operating pressure
Theo. intake capacity
Theo. Power output
Protection category
Device weight
Technical changes reserved!
Noise and vibration
m Warning: Noise can have serious effects on your
health. If the machine noise exceeds 85 dB (A), please
wear suitable hearing protection.
Noise data
Sound power level L
Sound pressure level L
Uncertainty K
8. Unpacking
technical
safety
• Open the packaging and carefully remove the
• Remove the packaging material, as well as the
www.scheppach.com
met, some non-obvious residual risks may still
remain.
information" and the "Proper use" together with the
operating manual as a whole are observed.
operating button may not be pressed when
inserting the plug in an outlet. Use the tool that is
recommended in this operating manual. This is
how to ensure that your machine provides optimum
performance.
machine is in operation.
Technical data
WA
pA
wa/pA
device.
packaging and transport safety devices (if present).
230 V~ 50 Hz
1100 W
S1
2850 min
-1
ca. 24 l
ca. 8 bar
ca. 200 l/min
ca. 63 l/min
IP 30
18,3 kg
97 dB(A)
83,4 dB(A)
2,16 / 3 dB(A)