OPERATING AND MAINTENANCE MANUAL
SH SERIES CENTRIFUGAL ELECTRIC PUMP
4. NOMENCLATURE
SH
2
4 T

5. ELECTRICAL WIRING

Caution:
Make sure that the voltage (V), frequency (Hz) and phase (PH) are in accordance with the labelled
voltage (V), frequency (Hz) and phase (PH).
The pump must be correctly earthed and protected against leakage.
The wiring must meet the current requirements.
Ensure correct electrical circuit.
6. STARTING, OPERATING AND STOPPING THE PUMP
Caution:
Dry operation is prohibited to avoid burning the mechanical seal.
It must be turned freely through the fan cover by means of a screwdriver.
When starting the pump, the clockwise rotation of the fan must be visible.
Fill the pump with water from the discharge valve.
Start the pump and set the delivery pressure to the required pressure.
Close the delivery valve before the pump stops.
7. MAINTENANCE
Warning:
It is strictly forbidden to start the pump frequently, the switch must be opened when the power is
cut off.
It is not allowed to use the suction valve to adjust the flow rate.
When the water is insufficient, the engine must be stopped.
If there is any abnormal noise, please stop the motor and check.
If the pump is used for long periods or low temperatures, the water must be drained to avoid dama-
ge to the pump body such as freezing.