T RO U B L E SHO OT IN G
How to solve simple problems
For symptoms not found in the table below or more severe problems, see
Complete User manual on www.bluewatergroup.com.
Symptom
No water comes from the
purified water faucet. The
system operation indicator
light is off.
No water comes from the
purified water faucet. The
system operation indicator
light is on.
No water comes from the
purified water faucet. The
system operation indicator
light flashes very quickly.
(0.1 sec ON, 0.1 sec OFF).
No water comes from the
purified water faucet. The
system operation indicator
light flashes quickly (0.5
sec ON, 0.5 sec OFF).
Water comes from the
purified water faucet. The
system operation indicator
light flashes quickly (0.5
sec ON, 0.5 sec OFF).
The system operation
indicator light flashes slowly
(2 sec ON, 2 sec OFF).
The flow rate from the
purified water faucet is low.
Too much continuous noise
during water purification.
Cause
Cleone is not connected to
power.
Cleone is not started.
An internal leak has been sensed.
Cleone has been automatically
stopped.
Cleone has been installed for the
first time, and the system is not
filled with water.
The water tubes are not
connected, or the connection is
made incorrectly.
Regular maintenance has not
been done. Prefilters are clogged.
The inlet water pressure is too
low, and the pump protection
system has stopped the inlet
water supply.
Cleone has stopped because the
water quality is low.
The water quality has decreased.
The filters must be replaced.
The purified water tank is
empty because of high water
consumption.
The air pressure in the purified
water tank is low.
It is necessary to do maintenance
on the booster pump.
11
Solution
Connect Cleone to an electrical
outlet and to the power adapter.
Make sure that the 24V DC
cable from the power adapter is
connected to the electrical power
socket on Cleone.
Move the power switch to On
(position "1").
Contact your Bluewater dealer
to repair the leak and reset the
system.
Wait for the system to be filled
with water.
Make sure that the connections
are made correctly.
Contact your Bluewater dealer to
do maintenance on Cleone.
Cleone will start to operate
as usual when the inlet water
pressure comes back. Flush
Cleone as described in Complete
User Manual.
Contact your Bluewater dealer for
service.
It is safe to use the purified water.
Contact your Bluewater dealer for
more information.
See "Regular maintenance" for
information about when to change
the filters. Replace the filters and
reset the filter indicator as described
in Complete User manual.
Upgrade to a larger tank or a high
capacity membrane.
Contact your Bluewater dealer to
restore the correct air pressure in
the purified water tank.
Contact your Bluewater dealer.
© Bluewater Group 2022
EN