Installation

Preparation
Before moving the oven, protect any finished flooring and
secure the oven door closed to prevent damage.
Use an appliance dolly to move the oven near the opening.
Place the appliance dolly on the side or back of the oven
to prevent damage. Remove and recycle packing materials.
Do not lift or carry the oven by the door handle.
OVEN DOOR REMOVAL
To lighten the load, the oven door can be removed.
Remove only if necessary. Door removal should be done
only by a certified installer or service technician. Do not lift
or carry the oven door by the door handle.
To remove, open the door completely. Rotate both hinge
locks back completely, remove the screw closest to the
hinge on both sides of the door, and pull the door forward.
Refer to the illustration below.
To reinstall, slide the door onto the hinges. Rotate the
hinge locks forward completely and install the screws.
SCREW
HINGE
LOCK
Oven door removal

Electrical Connection

WARNING
Verify power is disconnected from the electrical box
before proceeding.
Open the terminal box to expose the screws with corre-
sponding numbers. Run the cord through the strain relief
hole and into the terminal box.
For a single phase installation (line, neutral, ground):
Loosen the 1, 5, and ground screws. Attach the line to
position 1, the neutral wire to position 5, and attach the
ground to the corresponding ground screw.
For 3-phase installation (L1, L2, L3, neutral, ground):
Loosen the 1, 2, and 3 screws and remove the copper bars.
Loosen the 5 and ground screws. Attach L1 to position 1,
L2 to position 2, L3 to position 3, the neutral wire to posi-
tion 5, and attach the ground to the corresponding ground
screw.
After tightening the screws, tighten down the cord strain
relief and close the cover to the terminal box without
pinching any of the wires.
3N
˜
˜
L1
L1
L2
L3
N
N
Single phase installation
3-phase installation
WARNING
The copper bars must be removed from positions 1,
2, and 3 when connecting to 3-phase power.