4
ACCESSORIES
This machine is intended for use with the following accessories:
♦
Art 187+ extension art 1327 for current adjustment during MMA welding
♦
Art 1284.05. clamp + earth 35mm2 for MMA welding (Art. 520)
♦
Art 1281.04 clamp + earth 16mm2 for MMA welding (Art. 506)
This device is intended for welding in TIG mode. Connector TIG 3170241 is provided for Item No 520 (see diagram).
5
MAINTEINANCE
Any maintenance operation must be carried out by qualified personnel in compliance with standard CEI 26-29 (IEC
60974-4).
4�1 POWER SOURCE MAINTENANCE
In the case of maintenance inside the machine, make sure that the switch F is in position "O" and that the power cord
is disconnected from the mains.
It is also necessary to periodically clean the interior of the machine from the accumulated metal dust, using com-
pressed air.
4�2 PRECAUTIONS AFTER REPAIRS�
After making repairs, take care to organize the wiring so that there is secure insulation between the primary and sec-
ondary sides of the machine. Do not allow the wires to come into contact with moving parts or those that heat up
during operation. Reassemble all clamps as they were on the original machine, to prevent a connection from occurring
between the primary and secondary circuits should a wire accidentally break or be disconnected.
Also mount the screws with geared washers as on the original machine.
3301012/B
LOCK (3-8)
TIG CONNECTOR 3170241
START(1-9)
13