General Prerequisites For Operating The Devices - Festo EduTrainer 571826 Manual De Utilización

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

1 General prerequisites for operating the devices

General requirements for safe operation of the devices:
National regulations for operating electrical systems and equipment must be observed in commercial
facilities.
The laboratory or classroom must be overseen by a supervisor.
A supervisor is a qualified electrician or a person who has been trained in electrical engineering,
knows the respective safety requirements and safety regulations and
whose training has been documented accordingly.
The laboratory or the classroom must be equipped with the following devices:
An emergency-off device must be provided.
At least one emergency-off device must be located within, and one outside of the laboratory
or the classroom.
The laboratory or classroom must be secured so that operating voltage and compressed air supply
cannot be activated by any unauthorized persons, for example with:
A key switch
Lockable on-off valves
The laboratory or classroom must be protected by residual current devices (RCDs).
Electrical devices (e.g. power supply units, compressors and hydraulic power units) may
only be operated in training rooms which are equipped with residual current devices.
Type B residual current circuit breakers with a residual current of ≤ 30 mA must be used.
The laboratory or classroom must be protected by overcurrent protection devices.
Fuses or circuit breakers
No damaged or defective devices may be used.
Damaged devices must be barred from further use and removed from the laboratory or classroom.
Damaged connecting cables, pneumatic tubing and hydraulic hoses represent a safety
risk and must be removed from the laboratory or classroom.
18
© Festo Didactic 8049690
Tabla de contenido
loading

Tabla de contenido