4.4.2- Alarm Messages

In the following cases, the chlorinator shuts down and the alarm and acousti c alarm
LED is acti vated (automati c reset once the fault is solved):
"NO WATER FLOW"
"SHORT CIRCUIT"
"OPEN CIRCUIT"
"Chl. error"
Excess gas in the
electrolysis cell. It
may have occurred
The piping should be drained to eliminate
because the pump has
gas or accumulated water. Check the
shutdown. The gas is
pump
hydrogen gas which is
highly fl ammable.
Sensor cable of the cell
is incorrectly connected
Check the sensor cable (white cable)
or broken
Cell sensor is dirty
Clean. See maintenance
No water fl ow
Check the water system
The cell is incorrectly
Check wiring
connected
Turn off the equipment and remove the
Metal body in the cell
metal body from the plates
Check the cell connecti on and ensure that
Cell is incorrectly
cables and connecti on terminals are in
connected
good conditi on.
Cell is damaged or
Check the conditi on of the cell electrodes,
completely worn down
and replace it if any damage is observed.
Swimming pool water
Ensure that the water has salt and that it
with very low salt
is dissolved
concentrati on
Chlorine probe is
Check the cabling of the probe and the
incorrectly connected
probe itself. Check 5.1. It can work in
or damaged
manual mode if necessary
Leave the equipment to chlorate in
Water contains very low
manual mode for at least 2 hours. Check
redox potenti al
the chemical balance of the water.
(appendix 1)
The equipment does
Install a Redox or Free Chlorine probe, or
not have a probe and is
confi gure "manual" mode
in "automati c mode"