4.4.1- Warnings
Message:
"LACK OF SALT"
"EXCESS SALT"
"CLEANING"
"TEMPERATURE"
4.4.1.1- Additional warning messages
ORP or PPM value is
fl ashing
pH value is fl ashing
Value ---o (Water
temperature) is fl ashing
pH min
pH max
ORP min
ORP max
Filter ti me
Causes:
Lack of salt in the water
Incrustati ons or objects in the electrolysis
cell causing excess current
The electrolysis cell is worn
Excess salt in the water
Incrustati ons or objects in the electrolysis
cell causing excess current
The chlorinator is in the self-cleaning
process. The process lasts 5 minutes
The ambient temperature is >40º
The radiator fi ns are obstructed or are not
in a verti cal positi on.
The redox or free chlorine probe are
balanced in automati c mode. When the
probe is balanced, the value remains set
The pH probe is balancing. When the probe
is balanced, the value remains set
The value of the water temperature is
under 15º.
The equipment is working under the
minimum set value.
The equipment is working above the
maximum set value.
The equipment is working under the
minimum set value
The equipment is working above the
maximum set value
The equipment has switched off before the
ti me set in semiautomati c
Acti on required:
Add salt to the swimming pool
Clean the cell
Replace the electrolysis cell with a
new one
No acti on required if excess is not
very signifi cant
Clean the cell
None
Try and place the equipment
in another positi on where it is
not over 40º or perform forced
venti lati on. Leave the equipment
to rest for a few minutes. Consult
secti on number 4. Installati on
Place the equipment so that air is
circulated for correct cooling
None
None
None
Revisar el sistema de pH
Revisar el sistema de pH
Revisar sonda Redox
Revisar sonda Redox
Reanudar el ciclo de fi ltración
55 25