Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

Nominal voltage
Current consumption
Charging voltage
Float Charging Voltage
Service Mode Voltage
Reactivation Voltage
Max. charging current
Minimum battery voltage
Operational temperature
Cooling
Charging characteristic
Battery types
Battery capacity
Weight (without charging power)
On charge or service operation the battery must have at least 3V to enable the
charger to start.
The quality of output voltage and current of a charger is very important. Undesired
variations and ripples lead to warming up and to wear the positive terminal.
Berner Trading Holding GmbH
The
clean tension and current.
TELLERERKL
• HIGH FREQUENCY CHARGER BHFL75 portable.
• Main cable (2m) Schuko-Connector with protective contacts plugs
• Battery cable (3m) red/black with full isolation with metal terminal clamps.
This operating manual.
The charger must be protected from strong pollution, liquid and moisture.
Cause this may damage the internal electronics.
The charger is maintenance free. If the cables or parts are damaged they must be
replaced. The housing can only be cleaned with dry cloth. Don't use any liquid, or
conductive materials. Before cleaning disconnect the AC Supply and battery cables.

TECHNICAL DATA

180 V – 264 V 47-63 Hz
5,2 A (by maximum charging current)
14-15 V (± 0,3%) adjustable
min. 13.3 V (± 0,3%)
13,9 V ( 0,3%) adjustable
max.15,5 V ( 0,3%)
70 A (12 V) 35A (24V) 10A (6V) ± 3%
3 V
-20°C – 50°C
Fan controlled by temperature
IUoU
Lead-Acid, Lead-GEL, AGM
25-700 Ah
3,6
battery charger are characterised by a very
CONTENT
MAINTENANCE
26
Tabla de contenido
loading

Este manual también es adecuado para:

329145

Tabla de contenido