Berner BHFL75 Instrucciones De Empleo página 21

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

symbol „Charge" and the battery charging starts automatically.
In the display appears additionally the actual charging current, the charging voltage
and the currently loaded ampere hour.
If instead an error message comes „No Battery connected", was no battery, a
completely discharged battery (the voltage of the battery is less than 3V) or
the battery cables are incorrectly (reverse polarity) connected.
The charging operation starts automatically as soon as a functioning battery
is connected.
The filling level of the battery indicator displays the approximate status of the battery
Stage of charge < 70%
be won a conclusion about the state of the battery any time.
An intact battery will initially absorb the maximum charging current, depending on
Stage of charge < 90%
Once the battery symbol appears 100% the
battery is fully charged and the trickle charge
is active.
By pressing the graph button can the
charging current course be analysed any
time.
With the cource of the charging current and
the display of the charged ampere hour can
20
Stage of charge 100%
the state of charge for a
certain period.
Subsequently reduces the
charging current over
several hours to a
minimum value of 1 A.
Is for example the
charged capacity in
Tabla de contenido
loading

Este manual también es adecuado para:

329145

Tabla de contenido