more powerful device.
The service charge current course can be read from the diagram.
The service operation can be interrupted any time by pressing the "STOP" button.
The display returns to the basic menu.
By pulling the plug from the wall outlet, the charger is turned off.
Warning: This function only must be used by vehicle with disconnected 12V
lead-acid batteries, because the high charging voltage 15.6V constitutes a
danger to the 12-V on-board electronics in vehicle systems and car paints can
damaged by battery gassing and reduces the life of bulbs.
The reactivation is started by reconnecting the battery and confirming the
"Start" button. The display shows "REACTIVATION ACTIVE".
REACTIVATION (12V)
After selecting the reactivation appears on
the display the warning message.
Concluded lead-gel and AGM batteries
can not reactivated!
This function is intended to deeply
discharged
lead-acid batteries to reactivate.
Defective lead-acid batteries (cell short)
can not be reactivated.
24
After starting the SERVICE-Mode
appears in the right part of the
display the current service charge
voltage, and the service charge
rate.
If the actual charge current
exceeds the value of 70A 12V,
(35A 24V) the device has
reached its capacity. If a higher
power demand expected, the
device have to be replaced with a