Intended Use; Technical Data - Rothenberger ROSPIMATIC Instrucciones De Uso

Ocultar thumbs Ver también para ROSPIMATIC:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 16
Markings in this document
Danger
This sign warns against the danger of personal injuries.
Caution
This sign warns against the danger of property damage and damage to the environment.
Call for action

Intended use

Universally deployable for the cleaning of all pipes with a Ø 20 - 50 mm pipe diameter. This device may
only be used in accordance with the regulations as stated. Other applications are not permissible!

Technical data

Nominal consumption ...................................... 230 V
Performance ..................................................... 630 W
Speed: .............................................................. 0 – 950 1/min clockwise
Spiral rod diameter: .......................................... Ø 8 mm
Max. spiral rod diameter: .................................. 7,5 m
Typical evaluated acceleration
in hand/arm area..................................... < 2,5 m/s²
Noise pressure level........................................... 83 dB (A) Wear ear protection!
Protection class ................................................. IP 20
Operation category ........................................... S3 10%
Weight: ............................................................ approx. 5 kg
Subject to technical modifications!
Overview
1
Spiral rod holder
2
Drive
3
Control handle
Operating
 Plug mains plug into power supply.
A heavy starting torque is produced when the machine starts running! Exercise care
when starting up the machine, i.e. select a low speed and increase if required!
Inserting the spiral into the pipe :
 Tighten the pressure sensor (4) (+) and set the control handle (3) to forward motion (push handle
in the direction of the spiral container (1). The feeder is regulated continuously (forwards, neutral
and backwards) by means of the control handle (3).
Only tighten the pressure sensor (4) sufficiently to ensure that the spiral can no longer be pulled by
hand from the spiral container.
There must be a distance of approx. 20 cm between the cleaning equipment and the pipe
opening.
 Use one hand to grip the control handle (3) on the cleaning equipment. Use the other hand to start
the drill (2) moving slowly and rotating to the right.
The spiral should bore its way into the existing blockage and should not be pressed in.
 Increase the speed depending on the cleaning problem.
8
4
Pressure sensor
5
Spiral
ENGLISH
fig. A
fig. B
Tabla de contenido
loading

Este manual también es adecuado para:

7.8576

Tabla de contenido