6.2. CONTROLS AND DISPLAYS FOR CONFIGURATION

The confi guration and the respective set values are displayed by means of:
LED (1) for programming, as shown below:
LED reference
LED colour
Symbol on front
LED (4):
BUTTON (5):
PROGRAM button (8):
See the "Structure" chapter for the location of these components on the door unit.

6.3. READING/CONFIGURATION SEQUENCE

Each parameter is associated with a colour of the LEDs (1) for programming and the set value is indicated
by the LED (4) as follows:
LED (4): OFF
LED (4): ON STEADY
LED (4): ON BLINKING
The steps for reading or confi guring the device are shown below:
1. Press the PROGRAM button (8) briefl y (less than 2s): the LEDs (1) will blink on the door unit [A: red, B:
orange, C: red] to indicate that the device is in programming mode.
2. Press the BUTTON (5) again briefl y to select the parameter to be confi gured which can be identifi ed by
the LEDs associated with it according to the table shown in the following chapter.
3. Select the parameter and hold the BUTTON (5) pressed for longer (from 5 to 10 seconds) to set the
parameter as indicated visually by the LEDs (4).
4. Press the PROGRAM button (8) briefl y or wait for the timeout after 10 minutes to end confi guration
mode.
6.4. PARAMETER ASSOCIATED TO PROGRAMMING LED (1)
COLOUR
Parameter to be confi gured
Parameter 1: door unit type
Parameter 2: door unit ID
Parameter 3: door opener
Parameter 4: call button enabling
call button
Parameter 5:
association with
(*)
switchboard call
(*) Function only possible if door unit is confi gured as main unit.
14
Red or Green
LED for displaying the set parameter value;
button for changing and/or confi rming the parameter
button for starting the confi guration.
LED (1)
LED C: Green
LED C: Red
LED B: Orange
LED A: Green
LED A: Red
A
Orange
Parameter value
Main
Secondary
Address 0
Address 1
Privacy
Free
No button enabled
Only the calling button (7)
is enabled
Both buttons are enabled LEDs on blinking
Not active
Arm
B
Red or Green
LED state (4)
LEDs off
LEDs on steady
LEDs off
LEDs on steady
LEDs off
LEDs on steady
LEDs off
LEDs on steady
LEDs off
LEDs on steady
DS1083-118A
C
Tabla de contenido