11. PEDESTRIAN LOCK ACTUATION

The door unit has two terminals for managing the pedestrian door lock (SE+ and SE-). The electric lock is
operated in the following cases:
whenever the hall button is pressed (terminals PA);
when a door open command is received from an apartment station according to the confi guration
("free" or "privacy").

12. GARAGE GATE LOCK ACTUATION

The audio door unit has two terminals (SE2) connected to the contacts of a normally-open relay which can
be used to control a gate opening control unit (*). The relay is operated for 1 second after receiving the
garage door opening command according to the operating mode ("free" or "privacy") as the door lock.
(*) The relay is NOT suitable to control direct power loads and can only be used as control relay.

13. INSTALLATION CONSTRAINTS

Some installation constraints must be respected for installing the panel. The following are allowed for each
confi guration:
Panel with button modules
A total maximum number of 12 installed modules
One door unit module ref. 1083/39
A single ILA and voice synthesis module Ref. 1168/48;
A single proximity key reader module Ref. 1168/45;
Maximum insertion of 11 four-button expansion modules Ref. 1168/4 or eight-button modules Ref.
1168/8;
Maximum insertion of 11 door number modules Ref. 1168/50.

14. CONNECTION EXAMPLE

Rear view of the modules fi xed to the panel frame in tipped position.
9
16
8 cm long cord provided with
button module with expansion
unit Ref. 1168/4 and 1168/8
A
of the ILA and voice synthesis
module Ref. 1168/48 and of
the door number module Ref.
1168/50.
82 cm cord provided with ILA
B
and voice synthesis module
Ref. 1168/48.
38 cm long cord provided with
two-module frame Ref. 1168/62
and with casing with two-
module frame Ref. 1168/312.
58 cm long cord provided with
C
three or four-module frame Ref.
1168/63 or 1168/64) and of one-
row casings with three or four-
module frame (Ref. 1168/313 or
1168/314).