3. Repeat this operation for at least 4-5 or more times, according to your possibilities.
4. Then load more and more fuel (following in any case the provisions contained in the installation booklet concerning maximum load)
and, if possible, keep the lighting periods long avoiding, at least in this initial phase, short ON/OFF cycles.
5. During the first starts, no object should be leaned on the appliance and in detail on enameled surfaces. Enameled surfaces
must not be touched during heating.
6. Once the «break-in» has been completed, it is possible to use the product as the motor of a car, avoiding abrupt heating with excessive
loads.
To light the fire, it is suggested to use small wood pieces together with paper or other traded lighting means.
The openings for air (primary and secondary) must be opened together (you must open the eventual Ignition control, and butterfly valve
placed on the pipe of smokes exhaust). When the wood starts burning, you may load other fuels and adjust the air for combustion according
to the instructions on paragraph TECHNICAL DESCRIPTION.
Please always be present during this phase.
Never overload the appliance (see cap. TECHNICAL DESCRIPTION / hourly consumption). Too much fuel and too much air for
combustion can cause overheating and therefore damage the appliance. The warranty does not cover the damages due to
overheating of the equipment.

LOW EMISSION FIRE LIGHTING

Smokeless combustion is a way of lighting a fire able to significantly reduce the emission of harmful substances. The wood burns gradually
from the top downwards, so combustion is slower and more controlled. Burnt gases pass through the high temperatures of the flame and
therefore burn almost completely.
Place the logs in the hearth a certain distance apart as shown in the
or vertically in the case of tall narrow combustion chambers. Place the fire starter module on top of the pile, arranging the first logs in the
module at right angles to the pile of wood.
Fire STARTER MODULE. This fire starter module replaces a paper or cardboard starter.
Prepare four logs, 20 cm long with a cross section of 3 cm by 3 cm
right angles, with the fire lighter (wax impregnated wood fibre for example) in the middle. The fire can be lit with a match. If you want, you can
use thinner pieces of wood. In this case, you will need a larger quantity.
Keep the flue gas exhaust valve and combustion air regulator open.
After lighting the fire, leave the combustion air regulator open in the position shown in according to the instructions on paragraph TECHNICAL
DESCRIPTION
FUEL
Wood
IMPORTANT:
do not add further wood between one complete load and the next;
do not suffocate the fire by closing the air intakes;
regular cleaning by a chimney sweep reduces fine particle emissions.
These instructions are backed by ENERGIA Legno SVIZZERA

NORMAL OPERATION

After having positioned the registers correctly, insert the indicated hourly wood load avoiding overloads that cause anomalous stresses and
deformations (according to the instructions on paragraph TECHNICAL DESCRIPTION). You should always use the product with the door
closed in order to avoid damages due to overheating (forge effect). The inobservance of this rule makes the warranty expire.
For safety reasons the door of the appliances with constructive system 1, must be opened only for the loading of the fuel or for removing the
ashes, while during the operation and the rest, the door of the hearth must remain closed.
The appliances with constructive system 2 must be connected to their own flue. The operating with open door is allowed under supervision.
IMPORTANT: For safety reasons the door of the hearth can be opened only for the loading of the fuel. The hearth door must
always remain closed during operation or rest.
With the controls positioned on the front of the appliance it is possible to adjust the heat emission of the hearth. They have to be opened
according to the calorific need. The best combustion (with minimum emissions) is reached when, by loading the wood, most part of the air for
combustion flows through the secondary air register.
Never overload the appliance (see the hourly wood load in the table here below). Too much fuel and too much air for the combustion may
cause overheating and then damage the stove. You should always use the appliance with the door closed in order to avoid damages due to
overheating (forge effect). The inobservance of this rule makes the warranty expire.
The adjustment of the registers necessary to reach the rated calorific yield with a depression at the stack of 12 Pa 1,2mm of column of water)
is the following one: see chapter TECHNICAL DESCRIPTION. The appliance works as an intermittent operating appliance.
Besides the adjustment of the air for the combustion, the intensity of the combustion and consequently the thermal performance of the
device is influenced by the stack. A good draught of the stack requires a stricter adjustment of air for combustion, while a poor draught
requires a more precise adjustment of air for combustion.
To verify the good combustion, check whether the smoke coming out from the stack is transparent.
If it is white, it means that the device is not properly adjusted or the wood is too wet; if instead the smoke is gray or black, it signals that the
combustion is not complete (it is necessary a greater quantity of secondary air).
WARNING: When fuel is added onto the embers in the absence of a flame, a considerable amount of fumes may develop. Should
this happen, an explosive mixture of gas and air may form, and in extreme cases an explosion may occur. For safety reasons it is
advisable to perform a new lighting procedure with the use of small strips.
24
Picture
Picture
PRIMARY Air
PRE-ADJUSTED
www.energia-legno.ch
ENGLISH
7. Arrange the largest at the bottom and the smallest at the top,
7. Cross the four logs and place them on top of the pile of wood at
SECONDARY Air
PRE-ADJUSTED
TERTIARY air
PRE-ADJUSTED
Tabla de contenido
loading

Tabla de contenido