Panasonic EYFLA4A Manual De Instrucciones página 14

Destornillador de impacto inalámbrico/llave de impacto inalámbrica
Ocultar thumbs Ver también para EYFLA4A:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Radio signal range limitation function
on/off setting (EYFLA4AR, EYFLA5AR,
EYFLA5QR, EYFLA6PR)
1. Set the tool to configuration mode.
(See page 11.)
. Press the format button.
• The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and off.
Display
Battery indication lamp
3. Press the format button again.
• Radio signal range limitation function
on/off setting value will be displayed.
4. Press the
and
signal range limitation function on/off.
Radio signal
Display
range limitation
function mode
C0
OFF
C1
ON
Factory settings
• Radio signal range limitation function
setting: C0 (OFF)
NOTE:
• For more information about how to register
the tool and assembly qualifier, see the
assembly qualifier instruction manual.
buttons to set radio
Status
Tool is operational in the
absence of communica-
tions with the Assembly
Qualifier.
Tool is not operational
in the absence of com-
munications with the As-
sembly Qualifier.
Initializing All Settings
Factory settings
• Torque clutch setting: "F" (torque con-
trol function off)
• Interval setting: 0 (off)
• This section explains how to revert all tool
settings to their default values at the time of
shipment from the factory.
• The error display will be turned off.
1. Set the tool to configuration mode.
(See page 11.)
. Press the format button.
• The control panel will begin flashing.
Display: The letter "F" flashes on and off.
Battery indication lamp: The upper and
lower bars of the battery flash on and off.
Display
3. Press the OK button to accept the select-
ed setting.
• The control panel will stop flashing and
light up.
Checking Tool Settings
• This section describes how to have the
tool display current settings for approx-
imately 3 seconds when the tool is
stopped.
• You cannot check tool settings when the
control panel is turned off. First, engage
the switch briefly to reactivate the display.
Checking the sung point detection setting
1. Press the torque set button.
• Control panel display
Display: The torque set lights up.
Battery indication lamp: The upper and mid-
dle bars of the battery flash on and off.
Checking the interval
1. Press the interval set button.
• Control panel display
Display: The interval set lights up.
Battery indication lamp: The middle bar
of the battery flashes on and off.
- 14 -
Battery indication lamp
Tabla de contenido