Checking Burner Cap Placement
Check to make sure that there is no gap between the
burner parts. You may gently try to move the burner
parts from side to side to check if they are properly
placed.
Check the Installation
Check operation of electric igniters. Check flame
characteristics. Flame should be blue with no yellow
tip.
Yellow Flames:
Further adjustment is required.
Yellow Tips on Outer Cones:
Normal for LPG Gas.
Soft Blue Flames:
Normal for Natural Gas.
If the flame is completely or mostly yellow, verify that
the regulator is set for the correct fuel. After
adjustment, retest.
Some yellow streaking is normal during the initial
start-up. Allow unit to operate 4-5 minutes and re-
evaluate before making adjustments.
8
Service
Contact our Service department if your appliance
needs repair. Our central Customer Service Center
(see below) will also be happy to supply you with
details on a center close to you.
When you contact our Customer Service, please have
the E number and the FD number for your appliance
available. You can find the product data plate with
these numbers on the underside of the appliance.
Questions? Please contact us. We look forward to
hearing from you!
877-4-GAGGENAU
www.gaggenau-usa.com
5551 McFadden Avenue
Huntington Beach, CA 92649