SECTION 3 TORCH:
INSTALLATION
3T.01 Torch Connections
If necessary, connect the torch to the Power Sup-
ply. Connect only the model SL60 / Manual or
SL100 / Mechanical Torch to this power supply.
Maximum torch leads length is 100 feet / 30.5 m,
including extensions.
WARNING
Disconnect primary power at the
source before connecting the torch.
1. Align the ATC male connector (on the torch
lead) with the female receptacle. Push the
male connector into the female receptacle.
The connectors should push together with
a small amount of pressure.
2. Secure the connection by turning the lock-
ing nut clockwise until it clicks. DO NOT
use the locking nut to pull the connection
together. Do not use tools to secure the
connection.
Art # A-07885
Connecting the Torch to the Power Supply
3. The system is ready for operation.
Check Air Quality
To test the quality of air:
1.
/
Put the ON / OFF switch in the ON
(up) position.
2. Put the Function Control switch in the SET
position.
300x5395
3. Place a welding filter lens in front of the
Any oil or moisture in the air will be visible on
3T.02 Setting Up Mechanical Torch
The mechanical torch includes a positioning tube
with rack and pinch block assembly.
1. Mount the torch assembly on the cutting
2. To obtain a clean vertical cut, use a square
2
1
3. The proper torch parts (shield cup, tip, start
INSTALLATION
ESAB CUTMASTER 60
torch and turn on the air. Do not start an
arc!
the lens.
NOTE!
An adapter is required to be installed
in the power supply if converting
a hand torch system to operate a
machine torch.
WARNING
Disconnect primary power at the
source before disassembling the
torch or torch leads
table.
to align the torch perpendicular to the sur-
face of the workpiece.
Workpiece
Mechanical Torch Set - Up
cartridge, and electrode) must be installed
for the type of operation. Refer to Section
4T.07, Torch Parts Selection for details.
Pinch Block
Assembly
Square
A-02585
3T-1