SECTION 3 SYSTEM:
INSTALLATION
3.01 Unpacking
1. Use the packing lists to identify and ac-
count for each item.
2. Inspect each item for possible shipping
damage. If damage is evident, contact
your distributor and / or shipping company
before proceeding with the installation.
3. Record Power Supply and Torch model
and serial numbers, purchase date and
vendor name, in the information block at
the front of this manual.
3.02 Lifting Options
The Power Supply includes a handle for hand
lifting only. Be sure unit is lifted and transported
safely and securely.
WARNING
Do not touch live electrical parts.
Disconnect input power cord before
moving unit.
WARNING
!
FALLING EQUIPMENT can cause
serious personal injury and can
damage equipment.
HANDLE is not for mechanical lifting.
• Only persons of adequate physical strength
should lift the unit.
• Lift unit by the handles, using two hands. Do
not use straps for lifting.
• Use optional cart or similar device of ad-
equate capacity to move unit.
• Place unit on a proper skid and secure in
place before transporting with a fork lift or
other vehicle.
300x5395
3.03 Primary Input Power
Connections
CAUTION
!
C h e c k y o u r p o w e r s o u r c e f o r
correct voltage before plugging
in or connecting the unit. Check
the Voltage Selector at the rear of
the unit for correct setting before
plugging in or connecting the unit.
The primary power source, fuse,
and any extension cords used must
conform to local electrical code and
the recommended circuit protection
and wiring requirements as specified
in Section 2.
All units are shipped from the factory with a
380/400 Volt input power cable wired to the input
contactor in the three - phase configuration. The
following illustration and directions are for replac-
ing the input power cable.
Trifásico (3ø) e Ajuste dos Jumper
L1
L2
L3
L4
GND
Three Phase Input Power Wiring
A. Connections to Three Phase Input Power
WARNING
Disconnect input power from the
power supply and input cable before
attempting this procedure.
These instructions are for replacing a 380/400V
input power cable to the Power Supply for Three -
Phase input power.
1. Remove the Power Supply cover per in-
structions found in section 5.
2. Disconnect the original input power cable
from the main input contactor and the
chassis ground connection.
INSTALLATION
ESAB CUTMASTER 60
Jumper L1 -L4
L1
L2
L3
L4
3-1