NOTE!
For a secure seal, apply thread sealant to the fitting threads, according to the maker's
instructions. Do Not use Teflon tape as a thread sealer, as small particles of the tape may
break off and block the small air passages in the torch. Connect as follows:
Installing Optional Two - Stage Air Filter Kit
This optional two - stage air line filter is also for use on compressed air shop systems. Filter removes
moisture and contaminants to at least 5 microns.
Connect the air supply as follows:
1. Attach the Two Stage Filter bracket to the back of the power supply per instructions supplied
with the filter assembly.
NOTE!
For a secure seal, apply thread sealant to the fitting threads, according to manufacturer's
instructions. Do not use Teflon tape as a thread sealer, as small particles of the tape may
break off and block the small air passages in the torch.
2. Connect the two stage filter outlet hose to the inlet port of the Regulator / Filter Assembly.
3. Use customer - supplied fittings to connect the air line to the Filter. A 1/4 NPT to 1/4" hose
barbed fitting is shown as an example.
300x5395
Hose Clamp
Gas Supply
Hose
Optional Single - Stage Filter Installation
INSTALLATION
ESAB CUTMASTER 60
Regulator/Filter
Assembly
Inlet Port
Art # A-07944
1/4 NPT to 1/4"
(6mm) Fitting
3-3