Maintenance Chart - Bostitch CAP1645-OF Manual De Instrucciones

Compresor de aire sin aceite portátil
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

3. Remove hose and accessory.
Risk of unsafe operation. Firmly grasp air hose in hand when installing or discon-
necting to prevent hose whip.
4. Drain the air tank, see Draining Air Tank under Maintenance. Ensure air tank pressure
gauge reads 0 psi.
Risk of bursting. Drain air tank daily. Water will condense in air tank. If not
drained, water will corrode and weaken the air tank causing a risk of air tank rupture.
5. Allow the compressor to cool down.
6. Wipe air compressor clean and store in a safe, non-freezing area.
Risk of unsafe operation. Do not operate in vertical position. Vertical position is for
storage only.
MAINTENANCE
The following procedures must be followed when maintenance or service is
performed on the air compressor.
1. Ensure
Auto/Off
2. Remove air compressor plug from outlet.
3. Drain air tank.
4. Allow air compressor to cool down before starting service.
All compressed air systems contain maintenance parts (e.g., oil, filters, separa-
tors) that are periodically replaced. These used parts may contain substances that are regulated
and must be disposed of in accordance with local, state, and federal laws and regulations.
NOTE: Take note of the positions and locations of parts during disassembly to make reassembly
easier.
NOTE: Any service operations not included in this section should be performed by a BOSTITCH
factory service center or a BOSTITCH authorized service center

MAINTENANCE CHART

Procedure
Check safety valve
Inspect Air Filter (J)
Drain air tank
Check for unusual noise/vibration
Check for air leaks
Clean compressor exterior
Remove tank from service
1 - To check for air leaks apply a solution of soapy water around joints. While compressor is pumping
to pressure and after pressure cuts out, look for air bubbles to form.
2 - For more information, call
CHECKING SAFETY VALVE
Risk of bursting. If the Safety Valve (G) does not work properly, over-pressuriza-
tion may occur, causing air tank rupture or an explosion.
Risk from flying objects. Always wear certified safety equipment: ANSI Z87.1
eye protection (CAN/CSA Z94.3) with side shields when using the compressor.
Before starting compressor, pull the ring on the Safety Valve (G) to make sure that the Safety
Valve (G) operates freely.Before starting compressor, pull the ring on the Safety Valve (G) to make
sure that the Safety Valve (G) operates freely.
switch is in the OFF position.
1-800-556-6696.
Daily
Weekly
X
X
X
X
X 1
X
12
See tank warning
label
X 2
Tabla de contenido