Store compressor in a vertical or horzitional position.
FIG. 3B
A
B
Do not operate this unit until you read this instruction manual for safety,
operation and maintenance instructions.
PRE-START CHECKLIST (FIG. 1)
1. Ensure the Auto/Off switch (L) is in the OFF position.
2. Plug the power cord into the correct branch circuit receptacle. See Voltage and Circuit
Protection under Installation.
3. Ensure air tank is drained, see Draining Air Tank under Maintenance.
4. Ensure the drain valve (M) is closed.
5. Ensure safety valve (G) is functioning properly, see Checking Safety Valve (G) under
Maintenance.
6. Pull the regulator knob (F) out and turn counterclockwise until fully closed. Ensure
Regulated Pressure Gauge (D) reads 0 psi. Push knob in to lock in place.
7. Attach hose and accessories. NOTE: Always use a minimum 3/8" (9.5 mm) or greater air
hose rated at 300 psi.
Risk of unsafe operation. Firmly grasp air hose in hand when installing or
disconnecting to prevent hose whip.
Risk of unsafe operation. Do not use damaged or worn accessories.
Risk of Bursting. Too much air pressure causes a hazardous risk of bursting.
Check the manufacturer's maximum pressure rating for air tools and accessories. The Regulator
(F) outlet pressure setting must never exceed the maximum pressure rating of the tool or
accessory.
START-UP (FIG. 1)
1. Follow Pre-Start Checklist under Preparation for Use.
Risk of property damage. Do not operate in vertical position. Vertical position is
for storage only.
2. Move the Auto/Off switch to the AUTO position and allow tank pressure to build. Motor will
stop when tank pressure reaches cut-out pressure.
Risk of unsafe operation. Compressed air from the unit may contain wa ter con-
densation and oil mist. Do not spray un fil tered air at an item that could be damaged by moisture.
Some air op er ated tools or de vic es may require filtered air. Read the in struc tions for the air tool
or device.
3. Adjust regulator (F) to desired setting. See Regulator under Features.
SHUT-DOWN (FIG. 1)
1. Move Auto/Off switch (L) to the OFF position.
NOTE: If finished using compressor, follow Steps 2–6.
NOTE: When the unit has been turned off, it is normal to hear a short hiss of air being released.
NOTE: Unplug unit when not in use.
2. Pull the regulator knob (F) out and turn counterclockwise until fully closed. Ensure regulated
pressure gauge reads 0 psi. Push knob in to lock in place.