Tabla de contenido
Idiomas disponibles

Idiomas disponibles

protection

Operation condition
The protective device may trip and stop the appliance in the cases
listed below:
Heating
Outdoor air temperature is over 24°C
Outdoor air temperature is below -7°C
Room temperature is over 27°C
Cooling
Outdoor air temperature is over *43°C
Room temperature is below 21°C
Dry
Room temperature is below 18°C
*For Tropical (T3) climate condition models, the temperature point is
55°C instead of 43°C.
The temperature of some products is allowed beyond the range. In
specific situation, please consult your dealer.
If the air conditioner runs in COOLING or DRY mode having a door
or window opened for a long period when relative humidity is
above 80%, condensation water may drip down from the outlet.
noise pollution
• Install the air conditioner on a place that will fully support its
weight. This will make the appliance to run quietly.
• Install the outdoor unit in a place where the discharged air and
the operation noise will not annoy the neighbors.
• Do not place any obstacles in front of the outdoor unit air outlet
as this will increase the noise level.
features of protector
1. The protective device will be activated in the following situations:
• When restarting the unit after operation stops or when chang-
ing modes during operation. You must wait at least 3 minutes.
• Connect to power supply and turn on the unit, it may start 20
seconds later.
2. If all operation has stopped, press ON/OFF button again to restart.
Timer should be set again if it has been canceled.
95

Capítulos

Tabla de contenido
loading

Tabla de contenido