To modify one channel table, access the TV mode functions menu, turn the rotary
selector [4] to the Channel set function and press to activate it. The monitor will then
show the CHANNEL SET screen. Turn the rotary selector [4] to the desired table and
then press the rotary selector [4] again to activate.

4.9.4.8 Measurement Units

The PROLINK-3/3C
and channel power: dBµV, dBmV and dBm.
To select the units of measurement, access the TV mode functions menu, turn the
rotary selector [4] to select the Units function and press to activate it. The monitor will
show a screen labelled UNITS displaying the three available options (as well as the Exit
option). Turn the rotary selector [4] to the units you require, then press to activate it.

4.9.4.9 Power Off Mode (Manual power)

The PROLINK-3/3C
(unit disconnects automatically after 15 minutes without operating on any control).
To select the power-off mode, access the TV mode functions menu, turn the
rotary selector [4] to select the Manual power function and press to activate it. The
monitor will show a screen labelled POWER OFF displaying the two available options
(as well as the Exit option). Turn the rotary selector [4] to select the power-off mode you
require, then press to activate it.
4.9.4.10

C/N setup

To measure C/N the PROLINK-3/3C
mode:
C/N (Auto)
C/N (Reference noise)
To select C/N mode, access the TV mode functions menu, turn the rotary selector
[4] to the C/N setup function and press to activate it. The monitor will show a screen
labelled C/N SETUP displaying the two available options (as well as the Exit option).
Turn the rotary selector [4] to the mode you require, then press to activate it.
Page 68
Premium
offers three measurement units to measure level
Premium
offers two power-off modes: Manual and Automatic
Premium
The PROLINK-3/3C
frequency where noise level is measured, according
with:
f noise = f tuning - ½ Channel BW.
The user defines the frequency where noise level is
measured (by means of the Reference noise function).
This frequency will be used to measure noise level for
all channels.
USER'S MANUAL. PROLINK-3/3C
offers two different modes in TV
Premium
defines automatically the
Premium
06/2005