W
HEN THE AIR CONDITIONER IS NOT
GOING TO BE USED FOR A LONG TIME
1
Set to the highest temperature in manual COOL mode,
and operate for 3 to 4 hours.
This dries the inside of the unit.
2
Press
to stop the operation.
3
Turn off the breaker and/or disconnect the power sup-
ply plug.
4
Remove all batteries from the remote controller.
When using the air conditioner again:
1
Clean the air fi lters.
2
Check that the air inlet and outlet of the indoor and
outdoor units are not blocked.
3
Check that the ground is connected correctly.
S
PECIFICATIONS
Guaranteed operating range
95°F (35°C)
Upper limit
71°F (21.7°C) WB
Cooling
67°F (19.4°C) DB
Lower limit
57°F (13.9°C) WB
SG79Y951H01_EN.indd 10
All manuals and user guides at all-guides.com
Page 5
Page 8
MS-A09/12WA
Indoor
Outdoor
DB
115°F (46.1°C) DB
71°F (21.7°C) WB
67°F (19.4°C) DB
57°F (13.9°C) WB
I
NSTALLATION PLACE AND

ELECTRICAL WORK

Installation place

Avoid installing the air conditioner in the following places.
• Where there is much machine oil.
• Salty places such as the seaside.
• Where sulfi de gas is generated such as a hot spring.
• Where oil is splashed or where the area is fi lled with oily smoke.
• Where there is high-frequency or wireless equipment.
• Where the air from the outdoor unit air outlet is blocked.
• Where the operation sound or air from the outdoor unit does not bother the
house next door.
To prevent the effects
of a fl uorescent lamp,
keep as far apart as
possible.
3 ft
(1m)
or more
3 ft (1m)
or more
Cordless
phone or
Portable
phone
Radio
Electrical work
• Provide an exclusive circuit for the power supply of the air conditioner.
• Be sure to observe the breaker capacity.
If you have any questions, consult your dealer.
MSY-A15/17NA
Indoor
Outdoor
95°F (35°C)
DB
115°F (46.1°C) DB
67°F (19.4°C) DB
14°F (-10°C)
DB
The installation location of the outdoor unit should
be at least 10ft (3 m) away from the antennas for TV
sets, radios, etc. In areas where the reception is weak,
provide greater space between the outdoor unit and
the antenna of the affected device if operation of the air
conditioner interferes with radio or TV reception.
Inverter-type
fl uorescent lamp
wall, etc.
Well-
ventilated dry
place
Keep a space to
prevent the pic-
ture distortion or
4 in (100 mm)
the noise.
or more
8 in (200 mm)
TV
or more
10 ft (3 m)
or more
En-10
4/9/07 4:20:58 PM
Tabla de contenido
loading

Este manual también es adecuado para:

Ms-a12waMsy-a15naMsy-a17na