ELECTRICAL CONNECTIONS - WIRING DIAGRAMS
The boiler must be connected to an earthed, single-phase 230V-50 Hz mains supply by means of a three-
wire cable, ensuring that connections to the PHASE and NEUTRAL terminals are made correctly.
A omnipolar switch must be used with contacts opening to at least 3 mm.
The power lead must only be replaced by another with the following characteristics: "HAR H05 VV-F"
3 X 1.00 mm
2
. The ground wire shall be 2 cm longer than phase and neutral wires.
Installation must be made in compliance with SAFETY REGULATIONS IN FORCE.
Ground connections are compulsory. Connect the boiler to an efficient grounding system.
Voltage
Frequency
V
Hz
230
50
To gain access to the electrical panel which houses the power supply terminal block and any connection to
a room temperature thermostat, proceed as follows:
●
Disconnect the boiler power supply
●
Undo the two control panel fixing screws 1 (fig. 1)
●
Rotate the control panel until it comes up against the first
safety stop. Lift to release and rotate until it opens completely
(fig. 2).
NOTE: DO NOT FORCE THE PANEL AS THIS MIGHT
BREAK THE OPENING MECHANISM.
●
Undo the two cover attachment screws to gain access to
the electrical connections (fig. 3).
To gain access to the levels board and the IONO control unit
undo thw screws (3) from closure panel B (fig. 4). Furthermore,
to adjust the calibration potentiometers, by the aid of a screwdriver,
remove the corresponding protection plugs (4) (fig. 4).