Safety Information
Regional Requirements
WARNING
This product can expose you to chemicals including
lead, which is known to the State of California to cause
cancer and birth defects or other reproductive harm. For
more information go to
Safety
DO NOT DISCARD - GIVE TO USER
WARNING Read all safety warnings, instructions, il-
lustrations and specifications provided with this
product.
Failure to follow all instructions listed below may result
in electric shock, fire, property damage and/or serious
injury.
Save all warnings and instructions for future refer-
ence.
WARNING All locally legislated safety rules regard-
ing installation, operation and maintenance shall be
respected at all times.
Statement of Use
• For professional use only.
• This product and its accessories must not be modified in
any way.
• Do not use this product if it has been damaged.
• If the product data or hazard warning signs on the prod-
uct cease to be legible or become detached, replace with-
out delay.
• The product must only be installed, operated and ser-
viced by qualified personnel in an industrial environ-
ment.
Intended Use
This motor is designed to be incorporated into a fixed or
moving machine. It is either for right hand rotation only, left
hand rotation only, or reversible rotation and should be
mounted by the flange or threaded nose only, as appropriate.
No other use permitted.
The risk of motors being the source of ignition of a poten-
tially explosive atmosphere is extremely small. The user is
responsible for assessing the risks associated with the whole
machine into which the motor is to be incorporated.
4
www.P65Warnings.ca.gov
© Atlas Copco Industrial Technique AB - 9836 7281 00
LZB33-LB-AR0026-11 ATEX
Product Specific Instructions
Warning
WARNING Polymer hazard
The vanes in this product contain PTFE (a synthetic flu-
oropolymer). Due to wear, there might be PTFE parti-
cles inside the product. Heated PTFE can produce fumes
which may cause polymer fume fever with flu-like
symptoms, especially when smoking contaminated to-
bacco.
Health and Safety recommendations for PTFE must be
followed when handling vanes and other components:
Do not smoke when servicing this product
►
PTFE-particles must not come in contact with open
►
fire, glow or heat
Motor components must be washed with cleaning
►
fluid and not blown clear with an air line
Wash your hands before starting any other activity
►
IP Rating
The IP Rating of the air motors is set under pressurized con-
dition and excludes the outlet or attached silencer. If the mo-
tor will operate submerged or in heavy water jets, it's recom-
mended to lead the outlet away from water with a hose.
When submerged, always keep the motor pressurized with a
higher pressure than the corresponding depth.
Connecting the air supply
When the compressed air supply is connected to the inlet, the
direction of rotation will be as shown in the figure below. If
the exhaust air is to be piped away, a hose should be con-
nected to the exhaust outlet.
The compressed air supply should be connected to the corre-
sponding inlet for desired rotation direction, see figure be-
low. The inlet that is not in use, functions as an additional
outlet and must not be plugged.
Installation diagram
Reversible motor