Tabla De Contenido; Table Of Contents Introduction - Baker Hughes Druck DPI 880 Manual Del Usuario

Ocultar thumbs Ver también para Druck DPI 880:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 45
Introduction......................................................................... 1
Safety................................................................................... 2
Marks and symbols on the instrument............................... 2
To start ................................................................................ 2
Key to figure A1/A2 (Instrument) ....................................... 2
Key to figure A3 (Display).................................................. 3
Prepare the instrument...................................................... 3
Power on or off .................................................................. 3
Set up the basic operation................................................. 3
Select a task (Measure and/or supply).............................. 3
Set up the settings............................................................. 4
Operation............................................................................. 5
Electrical connections........................................................ 5
Communications port connections .................................... 5
Change the output values ................................................. 5
Measure/supply mA........................................................... 5
Measure/supply Volts or mV ............................................. 6
Measure/supply Hz or pulses ............................................ 7
RTD/Ohms connections .................................................... 7
Measure/simulate an RTD or Ohms.................................. 7
Thermocouple (TC) connections ....................................... 8
Measure/simulate a Thermocouple ................................... 8
Transmitter calibration....................................................... 8
Switch test ......................................................................... 8
UPM Pressure measurements .......................................... 9
Error indications .............................................................. 10
Maintenance...................................................................... 10
Clean the unit .................................................................. 10
Replace the batteries .................................................... 10
Calibration......................................................................... 11
Before you start ............................................................... 11
Procedures: mA input...................................................... 11
Procedures: mA output.................................................... 11
Procedures: mV/Volts input............................................. 12
Procedures: mV/Volts output........................................... 12
Procedures: Hz input/output............................................ 12
Procedures: CJ input....................................................... 12
Procedures: RTD (Ohms) input....................................... 13
Procedures: RTD (Ohms) output..................................... 13
Procedures: TC (mV) input/output................................... 13
Procedures: IDOS UMM.................................................. 13
Specification ..................................................................... 14
General............................................................................ 14
Electrical (A1 - Item 10)................................................... 14
Electrical connectors (A2) ............................................... 14
Temperature ranges (RTD) ............................................. 14
Resistance ranges (Ohms/RTD) ..................................... 15
Frequency ....................................................................... 15
Temperature ranges (TC)................................................ 16
mV (TC) range................................................................. 16
K0405 Revision B
Introduction
The DPI 880 Multi-function Calibrator is part of the Druck DPI
8xx series of hand held instruments.
This series of instruments uses Intelligent Digital Output
Sensor (IDOS) technology to give instant plug and play
functionality with a range of Universal Measurement Modules
(UMM). Example: the Universal Pressure Module (UPM).
The DPI 880 includes these functions:
Function
a Measure mA, Volts/mV, Hz/pulse count
* Supply mA, Volts/mV, Hz/pulse count
* Measure/simulate:
- a Resistance Temperature Detector (RTD):  or °C/°F
- a thermocouple (TC): mV or °C/°F
- a resistor ()
Cold Junction (CJ) compensation: Automatic/Manual
Step/Ramp functions: Automatic/Manual
Communications port: IDOS or RS232
Language selection (Refer to Table 1)
** Measure pressure/Leak test: External IDOS UPM
** Snapshot: Up to 1000 displays with a date/time stamp
250series resistor. Use this instrument together with a HART
communicator to set up and calibrate HART
Switch test
Other functions: Hold, Backlight
a
Refer to "Specification".
**
Optional item
®
®
devices.
1
[EN] English -
Tabla de contenido
loading

Tabla de contenido