Jung JLA-e 5/12 G Manual De Instrucciones página 59

Ocultar thumbs Ver también para JLA-e 5/12 G:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
Incorrect starting conditions or battery malfunctions
Fault
Connected power modules with
different voltage levels.
Battery with high apparent
resistance (internal resistance) -
sulfated battery.
Output voltage of the battery
>35% Unom/V/cell - Battery not
suitable.
Battery voltage >10% Unom/V/
cell, battery charging resumed
when drop to 9% Unom/V/cell
(
2.3V/cell).
Battery voltage during the
charging operation higher than the
entered limit (Umax) - Charging
operation is aborted.
Voltage monitors (absolute
values) of the individual modules
connected in parallel differ by
more than 3% from the nominal
voltage of the other modules.
If the battery temperature rises
to >(Tbat MAX+5)°C during the
charging operation, this is aborted.
If the temperature in the charging
device rises to >(Tint+5)°C, the
charging operation is aborted.
© JUNG Hebe- und Transporttechnik GmbH
Electrically driven trolleys JLA-e 5/12 G with stroke and JLA-e 15/30 G with stroke
F1x Cause
• Connected power modules with
F10
different voltage levels
• Faulty calibration
F11 • Strongly sulfated battery
• Battery with higher nominal voltage than
F12
set on the charging device
F13 • Battery is charged
• Battery defective
• Faulty connection between battery and
F14
charging device
• Charging device error
F15 • Voltage monitor error
• Ambient temperature too high
• Charging/discharging cycles run without
F16
breaks in a continuous sequence
• Charging current too high
• Ambient temperature too high
F17
• Charging device too dusty
Elimination
• Use correct modules
• Calibrate power modules
• Check the battery and consumption
• Measure the electrolyte density and the
voltage of the individual cells. Carry out
desulfating charging operation.
• Check the battery voltage
• Disconnect battery
• If it remains connected, the charging
process is automatically initiated aftervol-
tage drop
• Check the battery electrolyte density,
temperature, voltage of the individual cells
• Check the charging device settings, as
well as the connection to the battery
• Repair/replace the module
• Reduce the ambient temperature
• Longer breaks between the charging and
discharging of the battery
• Check the charging device settings
• Reduce the ambient temperature.
• Thoroughly clean the charging device.
• If the charging device is equipped with a
dust filter, check this and replace, if
necessary.
- 59 -
Tabla de contenido
loading

Este manual también es adecuado para:

Jla-e 5/30 g

Tabla de contenido