en-us
Preparing Kitchen Units
Connect Electrical Supply
Three wire connection
BO 450/451-612
1.
Connect red wire from oven to red electrical supply
wire (hot wire).
2.
Connect black wire from oven to black electrical
supply wire (hot wire).
3.
Connect yellow/green ground oven wire to bare
ground electrical supply wire.
Attach flexible conduit to the junction box.
To facilitate serviceability, the flex conduit must not be
shortened and should be routed to allow for temporary
removal of the oven.
Four wire connection
BO 480/481-613
1.
Connect red wire from oven to red electrical supply
wire (hot wire).
2.
Connect black wire from oven to black electrical
supply wire (hot wire).
3.
Connect white wire from oven to white electrical
supply wire (neutral).
4.
Connect yellow/green ground oven wire to electrical
supply ground wire.
Attach flexible conduit to the junction box.
To facilitate serviceability, the flex conduit must not be
shortened and should be routed to allow for temporary
removal of the oven.
Connection to the home network (LAN)
This appliance is network-compatible and can be
connected to the home network using a LAN cable (LAN
cable not included). Before installation, plug the LAN
cable into the socket on the rear of the appliance and
secure it using the strain relief. Connect the LAN cable
to a network socket.
Combination with combi-steam oven
Fit the combi-steam oven first. Pay attention to the combi-
steam oven's installation instructions.
For an installation depth of 550 mm (approx. 1.8 ft),
position the water hoses and the connecting cable in the
area of the housing cut-out.
10
All manuals and user guides at all-guides.com
Combination with warming drawer,
width 24" (60 cm)
Fit the warming drawer first. Pay attention to the warming
drawer's installation instructions.
Slide the oven onto the warming drawer and into the built-
in cabinet. When sliding it in, do not damage the warming
drawer's panel.
Combination with warming drawer,
width 30" (76 cm)
Installation BO/BS (width 30" (76 cm)) over warming
drawer WS only with dimensionally stable partition floor.
Check the Installation
9
Switch on the circuit breaker.
Verify that elements function properly.
Removal
1.
2.
3.
WARNING
Before you plug in an electrical cord or turn on
power supply, make sure all controls are in the OFF
position.
Disconnect the appliance from the power supply.
Undo the fastening screws.
Raise the appliance slightly and pull it out completely.