GB
H
1. Connection to the power supply must be made with a main switch
(H) it must be omnipolar and interrupt all contacts including neutral.
There must be a distance of at least 3 mm between open contacts,
and it must have a thermal magnetic safety switch or fuses which
are able to withstand the maximum power indicated on the plate
2.
Make sure that the power supply corresponds to that on the
technical features plate on the right side of the machine.
3.
Use an effective earthing system in compliance with local laws to
protect the safety of the operators and not damage the machine.
4. Do not use adapters, multiple sockets or extension cords.
5. The equipment must be included in an equipotential system, and
connected using a screw marked with the symbol
equipotential wire must be 10 mm²
6. When installation is completed the installer must check that the
machine is perfectly earthed
If the power supply cable (provided with the equipment) needs to
be replaced use another H07RN-F type with the same
dimensions.
For additional information see the wiring drawing.
2.3
ELECTRICAL CONNECTION
Page. 7
. The