Page. 6
2.2
ELECTRICAL CONNECTION FOR APPLIANCES WITH NO CABLE
a) Before connecting the equipment make sure that the electrical
system voltage and frequency match those on the machine
specifications plate located on the side panel.
b) It is compulsory to connect the machine to the power supply using a
dedicated omnipolar switch, in conformity with statutory safety
regulations. This switch must be automatic and with fuses that have a
minimum opening of 3mm between the contacts. The switch is not
furnished with the machine, it must be mounted on the wall in an easily
accessible position at a height between 0.6 and 1.70m.
c) Make sure that the electricity is not on before connecting the
power supply to the machine.
d1) Remove the front protection panel and the control panel by
removing the fixing screws.
d2) Unscrew the panel from the electrical panel and open it .
d3) Remove the PVC protection from the half-coils, insert the cable
through the fairlead and connect it to the half-coils labelled L1, and L3,
and hence attach the earth wire to the yellow-green terminal (N to blue
terminal).
d4) Replace the P.V.C protection and tighten the grommet
d5) Reclose the electrical panel.
NOTE:
Misconnecting the (N) and earth
appliance irreparably, and result in the invalidation of the
warranty!
d6) Check the tightening of the cables, thermal protections etc. as
they can loosen during transport.
d7) Replace the front panel and control panel with the provided
screws.
WARNING: the sizing of the switch and power supply
cable
needs
technical diagram.
to
be
done
consulting
wires may damage the
the
attached
GB