2A3 – MODELS WITH FREE FALL DRAINAGE
N.B.
The drainage line consists of a sump pit, free
flow, of proper size capable to dispose twice
the water flow indicated on the data diagram.
It must be close to the drain pipe of the
machine
without
bending,
jointing the pipe.
-
Drain line must reach sump pit with free flow
without constraints, stretching, bends, kinks, or
being forced.
-
Connect the waste outlet pipe to the main
drain pipe, fitting a trap, or place the outlet pipe
over an "S" trap set into the floor.
2A4 – MODELS WITH DRAIN PUMP
-
Position the outlet pipe at a height anywhere
between 750 and 1000mm from the floor. (Fig.7)
Fig. 7
2B - ELECTRICAL CONNECTION
N.B.
All contacts must be mechanically open,
ground line included, min. distance between
contacts 3 mm, with magnetic overload or
fuses, calibrated for a max, sustained current
agree with machine plat. It must be installed
outside the machine but close to it. It must
feed one machine only at time.
Machine cannot be connected to mains using
adapters, plug, cables or cable extensions not
properly sized and adequate to the machine
power requirements.
-
Verify main specifications must comply with
indicated requirements on the data plate located
inside of the front bottom panel of the machine
(par. ID/RATING/DATA PLATE), that exists for the
connection, a main breaker with proper size
suitable for the machine and a proper ground
system.
THE
RESPONSIBLE FOR DAMAGES OR INJURIES
CAUSED FOR IMPROPER GROUNDING. THE
GROUND
CONNECTIONS
stretching,
COMPLIANCE
REGULATIONS.
The line cable can be replaced only with a
spare cable supplied by the manufacturer.
For replacement indicate machine type,
machine
modifications of the installation. Power cable
cannot be stretched kinked, pressed, during
normal operation, service or anytime.
Earth equilibrating point on machine must
be connected to nearest appliance terminal
according to Safety Standards using a 2.5 –
10 mm.
WARNING!
MANUFACTURER
IS
AND
THE
ELECTRICAL
SHOULD
BE
WITH
NATIONAL
serial
number
and
NOT
IN
possible
8