operAtioN iNStructioNS
1. Running the impeller dry for as short as 30 seconds can ruin the impeller. Keep suction line as
short as possible.
Note: An easy way to prime the pump (wet impeller), if using a garden hose to fill the discharge
hose, is to elevate the discharge hose slightly to retain water and start the pump. Another method
would be to disconnect the discharge hose from the pump, making a U-bend of the discharge hose,
fill the hose, and then reconnect (without losing the water) to the pump. In both cases the water
behind the impeller will seal the pump and it will prime almost immediately.
2. Be sure hose attachments or piping connections are tight. Any leakage in suction side will prevent
pump from priming.

cAre AND MAiNteNANce

Always drain pump when not in use.
If pump is not going to be used for a month or longer, flush with fresh water and remove body
cover; take impeller out, clean inside body and apply a generous coating of petroleum jelly to both
inside body and impeller before replacing impeller in body.
The pump should be checked often for proper operation. If anything has changed since the
unit was new, the unit should be removed and repaired or replaced. Only qualified electricians
or servicemen should attempt to repair this unit. Improper repair and/or assembly can cause an
electrical shock hazard.
how to replace Brushes
Important: Motor brushes are normal wear items and must be replaced when necessary.
1. Call 1-877-903-0133 to obtain replacement part.
2. Be sure pump is disconnected from its source of power.
3. Unscrew brush cap. Remove brush and spring and
spring cover by pulling them straight out of the brush holder.
4. Install new brush and spring assembly with regard to curvature
of the front of the brush. Replace cap.
how to replace impeller
Replace impeller when it has been worn or damaged by foreign objects, improper liquid or dry
running.
1. Remove 4 face plate screws. Remove pump face plate.
2. Screw face plate back to pump head.
3. Connect hose to suction side of pump. Drop hose into water
and plug in pump.
4. Pump will prime after 10-15 seconds.
1
Brush cap
Face
Plate
Screws
(4)
7
Spring
Spring
2
Pump Head
Impeller
Face
Plate
Gasker
Brush cap