Start And Control Unit; Frequency Converter - Nederman FlexPAK 800 Manual Del Usuario

Ocultar thumbs Ver también para FlexPAK 800:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 152
All manuals and user guides at all-guides.com
15.
Outlet silencer after fan, see figure 4B.
16.
Control Filter and filter cartridge, see figure 4B.
17.
Pressure sensor, see figure 4B.
18.
Acoustic enclosure, see figure 4B.
19.
Cooling air hose from the frequency converter, see figure 4C.
20.
Compressed air supply, see figure 4C.
21.
Inlet, see figure 4C.
NOTE!
Depending on the FlexPAK 800/1000 DX, there is also an explosion protection device,
see figures 2A and 2B. See also section '3.3 Explosion protection'.
WARNING!
Risk of personal injury.
Depending on the FlexPAK 800/1000 DX model used, treat its explosion protection device
carefully so that it does not become damaged, see figure 2.
3.8

Start and control unit

The unit has a start and control unit, see figure 5. The start and control unit has the following
components:
1.
Transformer TR1, 60 W.
2.
Connection block for the transformer TR1.
3.
Transformer primary fuses F2 and F3, 6 A, slow.
4.
Programmable Logic Controller (PLC).
5.
Data Unit 2 (DU2), I/O module.
6.
AM 2 PT100, temperature sensor input expansion module.
7.
Filter cleaning/test start button.
8.
Standby/Running button, which is the On/Off button.
9.
Terminals: X1: 1-80.
10.
Fuse for 24 V DC accessory supply. Fuse F5, 1 A, slow.
11.
Fuse for Pilot Signal (PS) cable. Fuse F4, 1 A, fast.
12.
Terminals Protective Earth (PE).
3.9

Frequency converter

WARNING!
Risk of electric shock.
The frequency converter is not to be opened until 5 minutes after the supply voltage has been
disconnected. The capacitors inside the converter hold a very dangerous voltage until they have
discharged themselves.
Caution! Risk of equipment damage.
No parameters in the frequency converter may be adjusted without very detailed knowledge about
the consequences. Adjustment voids the warranty.
Caution! Risk of equipment damage.
The unit is not to be started if the cooling hose has been removed.
The frequency converter controls the unit's motor so that it operates efficiently, as well as
maintaining the unit's vacuum level to help prevent a dangerous underpressure from developing.
The manual for the frequency converter is enclosed.
NOTE!
Figures 4C and 6 show the cooling air hose that improves the cooling of the frequency
converter.
NOTE!
For parameter settings in the frequency converter, see the 'FlexPAK Frequency Converter
Parameter Table' that is a separate document included with the unit.
FlexPAK 800/1000 DX
EN
29
loading

Este manual también es adecuado para:

Flexpak 1000