3.9 Start and control unit
The unit has a start and control unit, see Figure 5. The
start and control unit has the following components:
1
Transformer TR1, 60 W.
2
Connection block for the transformer TR1.
3
Transformer primary fuses F2 and F3.
4 Terminals for an external emergency stop.
5
Programmable Logic Controller (PLC).
6
Data Unit 2 (DU2), I/O module.
7
AM 2 PT100, temperature sensor input expansion
module.
8 Filter cleaning/test start button.
9
Standby/Running button, which is the On/Off but-
ton.
10 Emergency switch.
11 Terminals: X1: 1-80.
12 Fuse for 24 V DC accessory supply: Fuse F5.
13 Fuse for Pilot Signal (PS) cable: Fuse F4.
14 Terminals Protective Earth (PE).
3.10 Frequency converter
WARNING! Risk of electric shock
The frequency converter is not to be opened
until 5 minutes after the supply voltage has
been disconnected. The capacitors inside the
converter hold a very dangerous voltage until
they have discharged themselves.
CAUTION! Risk of equipment damage
• Do not adjust any parameters in the fre-
quency converter without written author-
isation from the person responsible for this
product. See the . Any unauthorised adjust-
ment may void the warranty.
• The unit is not to be started if the cooling
hose has been removed.
Figure 4C
shows the cooling air hose that im-
proves the cooling of the frequency converter.
For parameter settings in the frequency con-
verter, see the 'FlexPAK Frequency Converter
Parameter Table' that is a separate document
included with the unit.
The frequency converter controls the unit's motor so
that it operates efficiently, as well as maintaining the
unit's vacuum level to help prevent a dangerous un-
derpressure from developing. The manual for the fre-
quency converter is enclosed.
FlexPAK 800/1000 DX
4 Accessories
The FlexPAK 800/1000 DX start and control unit is
prepared for the connection of Nederman accessories
and customer connections.
The installation of accessories, extra equipment, and
functions is described in the manual for each product
and according to the electrical diagrams that came
with the unit. Consult your local Nederman represent-
ative for available accessories.
The most common accessory is a PS cable, which al-
lows remote start/stop signalling from the valves on
the duct system. See also
and
Chapter 7 PLC settings
about messages and settings for accessories, and cus-
tomer connections.
5 Use
WARNING! Explosion risk
• Do not collect material that may cause igni-
tion or blocking. It is strictly prohibited to col-
lect material that may undergo dangerous
chemical or thermal reactions and/or self-ig-
nite.
• The filter should not be used for filtering
fumes from welding processes if it has been
used for combustible dust.
• Do not make any changes to this product
without consulting Nederman. Adding a relief
duct or changing the spacing or length of fil-
ter elements affects the calculations accord-
ing to EN 14491.
• Clean the unit and the area around it of any
spilled combustible dust before starting the
unit
WARNING! Risk of electric shock
• Personnel operating FlexPAK 800/1000 DX
are to pay special attention to avoiding dis-
charge of static electricity. The requirements
for the safe use and handling of combust-
ible dust are described in the explosion pro-
tection document. All personnel are to be in-
formed.
• Work with electric equipment is to be carried
out by a qualified electrician.
• Do not start the unit without connecting and
checking any disconnected grounding points.
See the Installation and Service Manual.
Chapter 6 PLC messages