6.4.4
Exhaust Air Temp High
The temperature of the air exiting the pump has exceeded the maximum allowable limit of 135ºC
(275ºF). When the 'Current Value' has become lower than 90°C (194ºF), press 'OK' to reset the
alarm. Check for the cooling air valve or PT100 sensor values.
Exhaust Air Temp High
Exceeded Limit 135˚C
Current Value
Reset OK ==>
NOTE!
For a description of the following displays please see the 'Installation and service
manual'.
6.4.5
External Fire Alarm Explosion Detected
External Fire Alarm
Explosion Detected
We: 15:07
Reset OK ==>
6.4.6
Low Pressure
Low Pressure
CAS<3Bar
Reset OK ==>
6.4.7
Bag Replacement Switch Time Out
Bag Replacement Switch
TimeOut
Tm 20:44:45m
Reset OK ==>
6.4.8
Control Filter Clogged
Control
Filter Clogged
Reset OK ==>
6.4.9
TVFD Error! Upper Slide Not Closed
TVFD Error!
Upper Slide
Not Closed
50˚C