EN
FlexPAK 800/1000 DX
7.2.3
H-Meter 1
Menu for setting the service interval. The default value is 2000 hours.
MI =2000h: The amount of time between service intervals.
H-Meter 1
MI = 2000h
7.2.4
DIR_Time
Menu for setting the DIR timer. The DIR timer is the amount of time before the unit goes from
Running mode into Idling mode when the pilot signal disappears.
T=10:00s: Time before DIR_Time is activated. The default setting is 10 seconds The minimum
setting is 5 seconds.
Ta=00:00: The elapsed time since the pilot signal disappeared.
DIR_Time
T = 10:00s
Ta = 00:00
7.2.5
SSR_Time
Menu for setting the SSR timer. The SSR timer is for the amount of time before the unit goes from
Idling mode to Standby mode when the pilot signal disappears.
T=12:00m: Time before SSR_Time is activated. The default setting is 12 minutes. The minimum
setting is 5 minutes.
Ta=00:00: The elapsed time since the pilot signal disappeared.
SSR_Time
T = 12:00m
Ta = 00:00
7.2.6
FltClean
Menu for setting time between automatic filter cleanings. If TH = 0, no filter cleaning is
performed. TH may not be set to 0 if PSIFC is set to 'On'.
TH=01:00s: Do not change the default setting of 1 second.
TL=60:00m: Time between automatic filter cleanings. The default setting is 60 minutes.
Ta=00:00: The elapsed time since the last automatic cleaning was activated
FltClean
TH = 01:00s
TL = 60:00m
Ta = 00:00