EN
FlexPAK 800/1000 DX
•
Hi Vacuum
•
Exhaust Air Temp High
•
Auto Cleaning Cycle To Intermittent Filter Heavy Clogged Check Filter
•
Bag Replacement Switch Time Out
•
Control Filter Clogged
•
Error! TVFD Gate
•
TVFD Error! Upper Slide Not Closed
•
TVFD Error! Upper Slide Not Open
•
TVFD Error! Lower Slide Not Closed
•
TVFD Error! Lower Slide Not Open
•
TVFD Error! Slides In Open Position
6.4.1
Frequency Conv Alarm
The frequency converter has detected a problem and has put the unit into Off mode. The following
list shows the most common problems:
•
Connection problem to main power supply.
•
Motor cable problem.
•
Power supply fault.
•
There is a problem with the frequency converter.
Frequency
Conv Alarm
Reset OK==>
6.4.2
PTC Detect Hi Motor Temp Unit Shut Down
The frequency converter has detected that the PTC sensors in the motor have reached the
maximum temperature for the unit (140°C), so the unit has been put into Off mode.
PTC Detect Hi Motor Temp
Unit Shut Down
Reset OK==>
6.4.3
Hi Vacuum
The maximum vacuum level has been activated, and the delay time for the vacuum alarm has
elapsed. Press 'OK' to reset the alarm.
Hi Vacuum
Level -36kPa
Reset OK==>