cutting width 3/32" (2.2 mm)
location hole 25/32" (20 mm)
standard blade thickness max. 1/16"
(1.8 mm)
suitable for speeds of up to 9500 min
Do not use abrasive discs.
This power tool may only be used by experts or
instructed persons.
Festool electric power tools must only be in­
stalled on work tables provided by Festool for
this purpose. If the tool is installed in another,
or self-made, work table, it can become unsta­
ble and result in serious accidents.
The user is liable for damage and acci­
dents caused by improper and non-in­
tended use.
7

Commissioning

WARNING
Unauthorised voltage or frequency!
Risk of accidents
► The mains voltage and the frequency of the
power source must correspond to the
specifications on the machine's name
plate.
► In North America, only Festool machines
with the voltage specifications 120 V/60 Hz
must be used.
CAUTION
Heating of the Plug it connection if bayonet
fitting is not completely locked
Risk of burns
► Before switching on the power tool, make
sure that the bayonet fitting at the mains
cable is closed fully and locked.
Always switch the machine off before
connecting or disconnecting the mains
power cable!
Connecting and detaching the mains power ca­
ble [1-11] see Fig. [2].
Slide the switch-on lock [1-6] upwards
and press the on/off switch [1-7] (press =
ON / release = OFF).
Pressing the switch-on lock unlocks the plung­
ing mechanism. The saw unit can then be
moved downwards. This causes the saw blade
to emerge from the protective cover.
-1
7.1

Extension Cord

If an extension cord is required, it must have
sufficient cross-section to prevent an excessive
drop in voltage or overheating. An excessive
drop in voltage reduces the output and can lead
to failure of the motor. The table below shows
you the correct cord diameter as a function of
the cord length for this tool.
Tab. 7.1: Cord Size in A.W.G
Tool`s Ampere Rating
3-6
6-8
8-10
10-12
12-16
Tab. 7.2: Wire Sizes in mm
Tool`s Ampere Rat­
ing
3-6
6-8
8-10
10-12
12-16
Use only U.L. and CSA listed extension cords.
Never use two extension cords together. In­
stead, use one long one.
The lower the AWG number, the
stronger the cord.
English
2
Cord Lenght in Feet
25
50
100
150
18
16
16
14
18
16
14
12
18
16
14
12
16
16
14
12
14
12
-
-
2
Cord Lenght in Meters
15
30
60
120
0.75 0.75 1.5 2.5
0.75 1.0
2.5 4.0
0.75 1.0
2.5 4.0
1.0
2.5
4.0 -
-
-
-
-