Further Steps For Troubleshooting; Spare Parts - Wilo EMU KS Serie Instrucciones De Instalación Y Funcionamiento

Ocultar thumbs Ver también para EMU KS Serie:
Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 67
1 Condensation build-up due to lengthy storage and/or
temperature fluctuations
• Operate the unit briefly (max.
5 min.) without moisture sensors
2 Expansion tank (optional for polder pumps) is too high
• Install the expansion tank no more than 10 m above
the bottom edge of the intake port
3 Increased leakage when running in new mechanical
shaft seals
• Change the oil
4 Defective moisture sensor cables
• Replace the moisture sensors
5 Mechanical shaft seal is defective
• Replace the mechanical shaft seal and contact the
factory

9.0.7 Further steps for troubleshooting

If the points listed here do not rectify the fault, con-
tact our customer service. They can help you as follows:
• Telephone or written support from customer service
• On-site support from customer service
• Inspection or repair of the unit at the factory
Please note that you may be charged for some ser-
vices provided by our customer support. For more
details, please contact customer service.

10 Spare parts

Spare parts can be ordered from the manufacturer's
customer service. To avoid queries and incorrect orders,
the serial and/or article number must always be sup-
plied.
Technical changes reserved!