Confirm Proper Operation; Operating Sequence - Kohler Sonata K-1683 Manual Del Usuario

Ocultar thumbs Ver también para Sonata K-1683:
Tabla de contenido
Idiomas disponibles

Idiomas disponibles

Fill with water 2" (5cm)
above the highest jet
Turn the jet trim
ring clockwise to
decrease the flow

9. Confirm Proper Operation

Fill the Whirlpool
NOTE: Please read these steps carefully before you operate your whirlpool.
- Position the jet nozzles so they face down toward the basin. Turn the jet trim rings fully counterclockwise.
- Fill the whirlpool to a water level at least 2" (5cm) above the top of the highest jet.
NOTE: The water temperature in the whirlpool should not exceed 104_F (40_C).

Operating Sequence

- Press the air actuator to turn on the whirlpool jets.
- Adjust each jet for optimum air/water mixture. Turn the trim ring clockwise to reduce the air flow, and counterclockwise to
increase the air flow.
- If equipped with an in-line heater, the heater will engage automatically when the pump is turned on and will disengage when
the pump is turned off. Water temperature must not exceed 104_F (40_C).
- Press the air actuator a second time to turn off the whirlpool.
NOTE: The optional K-1639 Timer Kit automatically stops the whirlpool after approximately 20 minutes of operation.
Kohler Co.
Position the jet
nozzles to direct the
water flow as
desired
Turn the jet trim ring
counterclockwise to
increase the flow
Press the air actuator to turn on and off
the whirlpool
9
B
1022475-2-
Tabla de contenido
loading

Este manual también es adecuado para:

Sonata k-1684Sonata k-1683-hSonata k-1684-h

Tabla de contenido