4. Install the Plumbing
CAUTION: Risk of property damage. Ensure a watertight seal on the whirlpool drain.
- Connect the drain to the trap according to the drain manufacturer's instructions.
NOTICE: An access panel will simplify future maintenance.
- Install the shower, fill spout, valving, and supply connections. Strap the supply connections to the stud framing. Provide
access to the connections for future maintenance. Install the trim.
- Connect the drain to the trap.
- Open the hot and cold water supplies, and check the connections for leakage. Install the faucet trim according to the
manufacturer's instructions.
- Run water into the whirlpool, and check the drain connections for leakage.
5. Make Electrical Connections
WARNING: Risk of electrical shock. To reduce the risk of electrical shock, connect the pump and in-line heater (if heater
option included) to properly grounded, grounding-type receptacles protected by Ground-Fault Circuit-Interrupters
(GFCI's). Do not remove the plugs' grounding pins. Do not use grounding adapters.
Pump Wiring
NOTE: The whirlpool model number is printed on a label near the whirlpool pump. This label also identifies the electrical
rating of the whirlpool.
- Your Kohler whirlpool bath is equipped with a cord and plug. All wiring of the pump and control has been completed at the
factory. A licensed electrician must install a GFCI-protected, 120 V, 15 A, grounded outlet. No other load should be on this
circuit. Locate the outlet behind the whirlpool, and within 24" (61cm) of the pump.
- Plug the pump into this outlet.
NOTE: Make sure the air actuator tubing is securely attached to the pump, and is not kinked or damaged.
- If a K-1639 Timer Kit will be used, install it now according to the instructions packed with the timer kit.
In-line Heater Wiring
- "H" Models: The in-line heater is equipped with a cord and plug. All wiring of the heater has been completed at the factory.
A licensed electrician must install a GFCI-protected, 120 V, 15 A, grounded outlet. No other load should be on this circuit.
Locate the outlet behind the whirlpool, and within 24" (61cm) of the heater.
- Plug the in-line heater into this outlet.
Kohler Co.
Plug the in- -line heater
into this outlet.
7
Plug the pump into this outlet
Install a GFCI- -protected 120 V, 15
A grounded outlet. Install a second
GFCI- -protected outlet for "H"
models for the in- -line heater.
Bond in accordance
with applicable codes
Make sure air actuator tubing is
securely attached to the pump
B
1022475-2-