Installation Diagram - Mitsubishi Electric MFZ-KA25VA Manual De Instrucciones

Ocultar thumbs Ver también para MFZ-KA25VA:
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 33
Power supply *1
Model
Rated
Frequency
Voltage
MFZ-KA25/35VA
230 V
50 Hz
MFZ-KA50VA
*1 Connect to the power switch which has a gap of 3 mm or more when open to
interrupt the source power phase. (When the power switch is shut off, it must
interrupt all phases.)
*2 Use wires in conformity with design 60245 IEC 57.
*4 Use a copper pipe or a copper-alloy seamless pipe.

1-5. INSTALLATION DIAGRAM

SUZ-KA25/35VA (H)
Units should be installed by licensed contractor
according to local code requirements.
ACCESSORIES
Check the following parts before installation.
(1) Drain hose
(2) Remote controller holder
Fixing screw for (2) 3.5 × 16 mm
(3)
(Black)
(4) Pipe cover
(5) Band
(6) Battery (AAA) for (12)
(7) Indoor unit mounting bracket
(8) Fixing screw for (7) 4 × 25 mm
(9)
(10) Washer of (9)
(11) Felt tape (For left or left-rear piping)
(12) Wireless remote controller
(13)
Pipe size
(thickness *3, *4)
Indoor/outdoor con-
Gas
necting wire
ø9.52 mm (0.8 mm)
4-core
2
1.5 mm
ø12.7 mm (1.0 mm)
PARTS TO BE PROVIDED AT YOUR SITE
1
(A) Indoor/outdoor unit connecting wire*
1
(B) Extension pipe
(C) Wall hole sleeve
2
(D) Wall hole cover
(E)
1
2
(F) Fixing screw for (E) 4 × 20 mm
2
(G) Piping tape
1
(H) Putty
5
Drain hose
(I)
(or soft PVC hose, 15 mm inner
4
dia. or hard PVC pipe VP16)
4
(J) Refrigeration oil
1
1
* Note:
Place indoor/outdoor unit connecting wire (A) and power supply
1
cord at least 1 m away from the TV antenna wire.
Pipe length and height difference *5, *6
Max. pipe
Max. height
Liquid
length
difference
20 m
ø6.35 mm
(0.8 mm)
30 m
*5 Be careful not to crush or bend the pipe during pipe bending.
*6 Refrigerant pipe bending radius must be 100 mm or more.
cause dew drippage.
Be sure to use wall hole sleeve (C) to
prevent indoor/outdoor connecting wire (A)
from contacting metal parts in the wall and
to prevent damage by rodents in case the
wall is hollow.
After the leak test, apply insulating mate-
rial tightly so that there is no gap.
When the piping is to be attached to a
wall containing metals (tin plated) or metal
netting, use a chemically treated wooden
piece 20 mm or thicker between the wall
and the piping or wrap 7 to 8 turns of
insulation vinyl tape around the piping.
To use existing piping, perform COOL
operation for 30 minutes and pump down
before removing the old air conditioner.
for new refrigerant.
1
1
1
1
2 to 5
2 to 5
1
1
1 or 2
1
Insulation
thickness *7, *8
12 m
8 mm
15 m
Wall hole
sleeve (C)
Wall hole cover (D)
Seal the wall hole
Indoor unit
gap with putty (H).
Fix the pipe to wall
band (E).
Cut off the
extra length.
(E)
Fixing screw
(F)
3
loading