07. Keep the n key pressed and wait for the motor to perform 3 movements. Now re-
lease the key;
08. Keep the n key pressed and wait for the motor to perform 4 movements. Now re-
lease the key;
09. Keep the t key pressed and wait for the motor to perform 5 movements. Then re-
lease the key.
Note – You can quit the procedure at any time by simply waiting for 15 seconds, after
which the motor moves 6 times and cancels the procedure.
6
OPTIONAL ACCESSORIES
6.1 • Climate sensors for wind, sun, rain
WARNING – The climate sensors must not be considered safety devices capable of elimi-
nating failures in the rolling shutter caused by rain or strong wind; in fact a mere power out-
age will prevent the awning from moving. Consequently, these sensors must be considered
components of an automation device for protecting the awning. The manufacturer declines all
liability for any material damages caused by atmospheric events not detected by the sensors.
6.1.1 - Definitions and conventions
• Manual "Sun On" Command = enables reception, by the motor, of automatic
commands transmitted by the "Sun" sensor if present in the installation. When recep-
tion is enabled, the user can send manual commands at any time: these override the
automatic operation of the automated device.
• Manual "Sun Off" Command = disables reception, by the motor, of automatic
commands transmitted by the "Sun" sensor if present in the installation. When the re-
ception is disabled, the automated device operates exclusively with the manual com-
mands sent by the user. The "Wind" and "Rain" sensors cannot be disabled because
they protect the automated device from these atmospheric phenomena.
• "Above-threshold" intensity of sun/wind = condition where the intensity
of the atmospheric phenomenon corresponds to high values above the set threshold.
• "Below-threshold" intensity of sun/wind = condition where the intensity
of the atmospheric phenomenon corresponds to low values below the set threshold.
• "Wind protection" = a condition in which the system inhibits all the awning open-
ing commands because of the over threshold wind intensity.
• "Presence of rain" = a condition in which the system detects the presence of
rain, with respect to the previous condition of "absence of rain".
• "Manual command" = UP, DOWN or Stop command sent by the user by means
of a transmitter.
6.1.2 - Behaviour of the motor in each kind of weather condition
The climate sensors allow you to automate awning/shutter operation in relation to the
current weather conditions.
For all sensors, the actuation setpoints must be programmed on the sensors themselves.
6.1.2.1 - Response of the automation to the Sun sensor (fig. 5)
When the intensity of the sunlight exceeds the set threshold for at least two minutes, the
motor automatically lowers the awning/shutter.
When the intensity of the sunlight drops below the specified hysteresis threshold (around
50% of the threshold value) and remains there for at least 15 minutes continuously, the
motor automatically raises the awning/shutter.
Momentary reductions in sunlight intensity for less than 15 minutes, do not affect the
overall cycle.
Manual commands generated by the user are in addition to the automatic commands.
6.1.2.2 - Response of the automation to the Rain sensor (fig. 6)
The presence of rain causes a transition from the "non-rain" state to the "rain" state.
When the motor receives the "presence of rain" information, it activates the command
programmed in the motor for this state, i.e. it opens or closes the awning/shutter.
Programming the rain detection actuation direction
01. Keep the n key pressed and wait for the motor to perform 2 movements. Now re-
lease the key.
02. Keep the n key pressed and wait for the motor to perform 3 movements. Now re-
lease the key.
03. Hold down keys n + s and wait for the motor to move two times. Then release the key.
a. Hold down key s, activate RDC, and wait for the motor to run 3 movements.
Then release the key.
b. Hold down key t, deactivate RDC, and wait for the motor to run 3 movements.
Then release the key.
Note – You can quit the procedure at any time by simply waiting for 15 seconds, after
which the motor moves 6 times and cancels the procedure.
6.1.2.3 - Response of the automation to the Wind sensor (fig. 7)
If the wind exceeds the setpoint value, the automation closes the awning. With wind
protection activated, the manual commands are deactivated and it is not possible to
open the awning.
At the end of the barring period, the manual commands are reactivated and after 15
minutes, automatic operation is restored.