Installation Instructions - Utilitech 0003139 Manual De Instrucciones

Tabla de contenido
Idiomas disponibles

Idiomas disponibles

iNStALLAtioN iNStructioNS

1. Remove 2 plastic thread protectors, one
from the top outlet hole on pump (A) and one
from the inlet/suction hole on pump (A).
2. Remove 4 screws from terminal box on
pump (A).
3. Check voltage of pump (A); the wall plug
should be 115 volts and the wire-to-box
should be 230 volts. Look at switch inside
terminal box to flip to 115V if needed.
4. Replace terminal box cover on pump (A) with
4 screws removed in step 2.
5. Turn pump (A) on side so pressure switch
is facing the ceiling. Loosen screw and
remove cover.
6. Take power cord that will be plugged into the
wall and put it through the rubber hole on the
left side of the pressure switch.
1
Outlet Hole - 1"
to Tank/House
Inlet/
Suction Hole
2
Terminal Box Screws
3
4
5
Pressure Switch Screw
6
Rubber Hole
Power Cord
from House
Outlet
7
A
A
A
Pressure Switch Cover
A