- While using the connector and other personal protective devices, the user must al-
ways remain below the anchor point (fig.5). The position and the height of the anchor
point from the ground, must be calculated in the view of a possible fall, taking into ac-
count the length of the rope and of the devices connected to the rope, any dangerous
obstacles, and the possibility of a "swinging" effect. The work must be carried out in
such way as to minimize both the potential fall and potential fall distance.
- Avoid rope slack above the ascender.
- The full body harness complying EN 361 is the only acceptable body retaining device
that can be used in a fall arrest system.
- Verify that a technical identification and control card in conformity with standard
EN 365:2004 is provided with the product. This card must be filled in and kept upda-
ted by the user. If the card is missing, do not use the device.
- Ascenders (EN12841/B) shall undergo periodical in-depth inspection carried out by
authorized person at least every 12 months.
- Any excessive or dynamic loading may damage the anchor line (pic. 8).
MATERIALS: All the materials and treatments used are antiallergenic; they do not cau-
se skin irritations or sensitivity. The ascenders are made of anodized light alloy; stainless
steel and plastic. This product is designed for use in normal atmospheric conditions
(conditions normally tolerated by man).
MAINTENANCE (fig. 9): Always replace the ascender after a fall (or any other big load)
even if no defect or damage is visible. The possibility of re-using must be authorized
exclusively by the producer with a prior written consent that reserves the right to carry
out appropriate examinations and testing. Any repair shall only be carried out in accor-
dance with producer's procedures.
Clean the ascender with soft water and dry it with a non-abrasive cloth. LUBRICATE
the mobile components with a specific silicone based lubricant (ensure, the lubricant
does not come onto places, which are in direct contact with the rope). If the ascender
comes in contact with salt water, wash it immediately and lubricate it.
All necessary repairs shall be carried out by competent person authorized by producer
according to the instructions provided by producer.
DISINFECTION: Dissolve a disinfectant which contains quaternary ammonium salts in
warm water (max. 20 °C). Soak the ascender in this solution for one hour. Rinse with
potable water and dry it with a clean cloth.
STORAGE AND TRANSPORT: Store the product in a cool, dry, well-aired place. There
must not be any corrosive or solvent substances or heat sources (max. 100 °C) in the
storage place.
The connector must not come in contact with other sharp objects which could damage
it. Never store the equipment before having thoroughly dried it and avoid storing it in
places with a high saline concentration. Except for the above-mentioned indications,
there are no special precautions to be used during the transport.
Avoid leaving your equipment in a car or in a closed place exposed to the sun.
LIFETIME: Lifetime of this product is not strictly limited by the manufacturer. Depending
on the condition of the product and its history it may be necessary to retire it immediate-
ly (e.g. after hard fall, visible signs of damage...). Lifetime of this product can be influen-
ced by various factors such as: frequent or improper use; usage environment (humidity,
freezing, ice); wear; corrosion; serious stress with relative deformation; exposure to heat
sources; improper storage; etc.
WARNING: Bare in mind that after one single extreme event, your equipment could
result unsuitable for further use.