Important Notes On Operation; Fitting And Transportation; Sensor Head Position; Connection - Bosch FWA 9000 Manual Del Usuario

Tabla de contenido
Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 40
en |
20 | FWA 9000 | Product description
3.3.2

Important notes on operation

!
Check the sensor heads for condensation before
switching on.
In the event of moisture, wait for the moisture on
the measuring system to evaporate.
!
Do not place any objects on the protective laser
housing.
3.3.3

Fitting and transportation

!
Pick up the sensor heads only by way of the unit
handle.
!
Transport with care.
Avoid impact on the sensor heads.
Take care not to drop the sensors.
3.3.4

Sensor head position

!
The sensor must be screwed to the adapter plate.
!
The sensor head is to be moved in longitudinal and
transverse direction only by way of the unit handle.
1
3
Abb. 5:
Measurement bay sensor head position
1 Front left sensor head
2 Front right sensor head
3 Rear left sensor head
4 Rear right sensor head
|
1 690 906 002
2017-07-04
3.3.5

Connection

i
The sensor head cables must be connected:
Sensor
Front left
Front right
Rear left
Rear right
i
The sensor heads must be switched on.
3.3.6

Status LED:

Status
Switch on sensor heads
Establishing
sensor <-> trolley link
Wheel alignment unit ready
i
The PC/laptop in the trolley must be on and the
wheel alignment program started.
3.4

Control cabinet

4
1
1 Master switch
2 Malfunction indicator light
i
Operation:
1. Switch on electrical cabinet.
2. Start the PC/laptop.
i
After use:
3. Shut down PC in the equipment trolley.
4. Switch off the electrical cabinet.
!
The electrical cabinet must be turned off when it is
not in use.
!
The ground fault interrupter (GFI) must be checked
every 6 months. The check must be performed by an
electrically qualified person.
Voltage
Data
Turntable
X
X
x
X
X
x
X
X
X
X
Color
Behavior
Orange
Lit
Orange <->
Flashing
Green
Green
Lit
2
Robert Bosch GmbH
Tabla de contenido
loading

Tabla de contenido