Operation
Attention!
Prior to use, check that the specifications of your
mains power supply correspond to the mains
voltage and mains frequency indicated on the
name plate.
HLG 1600 BASIC
S itching on
▸
Set the air quantity level at the switch [4].
The temperature is permanently pre-set for both air
3
quantity levels and cannot be changed.
Air quantity level 1 350 °C
Air quantity level 2 550 °C
▸
Allow the device to heat up for 3 minutes before
use.
S itching o
▸
Set the switch [4] to 0.
▸
Allow the device to cool down after use. To do so,
position it on its support points [3].
HLG 2000 COMPACT
S itching on
▸
Set the air quantity level at the switch [4].
▸
Set the temperature at the rotary knob [5].
It can be set from 80 - 620 °C in both air uantity
3
level settings. The scale [6] is for orientation:
Position 1: Temperature about 80 °C
Position 9: Temperature about 620 °C
▸
Allow the device to heat up for 3 minutes before
use.
S itching o
▸
Turn the rotary knob to 0.
▸
Position the device on its support points (see
section Setting the device down ) and leave it to
continue running for 5 minutes with the selected
air quantity level so that the device cools down.
▸
Set the switch [4] to 0.
HLG 2300-E POWER
S itching on
▸
Position the switch [4] at level 2 (work level).
▸
Set the air quantity level and the temperature
(see sections Adjusting the temperature and
Adjusting the air uantity )
14
S itching o
Information
Level 1 should be used for quick device
cooling. It is not necessary to decrease
the temperature via the display when
using it.
▸
Set the switch [4] to level 1.
▸
Position the device on the support points (see
section Setting the device down ) and leave it to
continue running for 5 minutes.
▸
Set the switch [4] to 0.
Adjusting the temperature
▸
Set the desired temperature using button "+" or "-".
The device heats up (symbol
3
down symbol (
flashes).
As soon as the desired temperature is reached,
3
the symbol stops flashing.
Adjusting the air uantity
▸
Press the selection button "".
Symbol
flashes.
3
▸
Set the desired air quantity using button "+" or "-"
(there are 5 selectable levels).
▸
Confirm with selection button "" or wait until the
symbol
comes on permanently.
The selected air quantity is displayed.
3
Standby operation
Switching on standby operation.
▸
Keep the selection button "" pressed for at least
2 seconds.
The symbol
appears in the display.
3
Standby operation is activated.
3
Switching o standby operation
▸
Press the selection button "".
The symbol
disappears in the display.
3
Standby operation is switched o .
3
Configuring the device
▸
Set the switch [4] to 0.
▸
Press the "+" and "-" buttons simultaneously and
set the switch [4] to level 1 while both buttons are
depressed.
Device configuration C0 appears on the
3
display.
▸
To access the next configuration, press the "+"
button.
▸
To access the previous configuration, press the "-"
button.
flashes) or cools